Upper airway reconstruction using long-range optical coherence tomography: Effects of airway curvature on airflow resistance.

Kimbell Julia S, Basu Saikat, Garcia Guilherme J M, Frank-Ito Dennis O, Lazarow Frances, Su Erica, Protsenko Dimitry, Chen Zhongping, Rhee John S, Wong Brian J

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVES

Adenotonsillectomy (AT) is commonly used to treat upper airway obstruction in children, but selection of patients who will benefit most from AT is challenging. The need for diagnostic evaluation tools without sedation, radiation, or high costs has motivated the development of long-range optical coherence tomography (LR-OCT), providing real-time cross-sectional airway imaging during endoscopy. Since the endoscope channel location is not tracked in conventional LR-OCT, airway curvature must be estimated and may affect predicted airway resistance. The study objective was to assess effects of three realistic airway curvatures on predicted airway resistance using computational fluid dynamics (CFD) in LR-OCT reconstructions of the upper airways of pediatric patients, before and after AT.

METHODS

Eight subjects (five males, three females, aged 4-9 years) were imaged using LR-OCT before and after AT during sedated endoscopy. Three-dimensional (3D) airway reconstructions included three airway curvatures. Steady-state, inspiratory airflow simulations were conducted under laminar conditions, along with turbulent simulations for one subject using the k-ω turbulence model. Airway resistance (pressure drop/flow) was compared using two-tailed Wilcoxon signed rank tests.

RESULTS

Regardless of the airway curvatures, CFD findings corroborate a surgical end-goal with computed post-operative airway resistance significantly less than pre-operative (P < 0.01). The individual resistances did not vary significantly for different airway curvatures (P > 0.25). Resistances computed using turbulent simulations differed from laminar results by less than ∼5%.

CONCLUSIONS

The results suggest that reconstruction of the upper airways from LR-OCT imaging data may not need to account for airway curvature to be predictive of surgical effects on airway resistance. Lasers Surg. Med. 51:150-160, 2019. © 2018 Wiley Periodicals, Inc.

Для цитирования: Kimbell Julia S, Basu Saikat, Garcia Guilherme J M, Frank-Ito Dennis O, Lazarow Frances, Su Erica, Protsenko Dimitry, Chen Zhongping, Rhee John S, Wong Brian J. Upper airway reconstruction using long-range optical coherence tomography: Effects of airway curvature on airflow resistance.. Lasers in surgery and medicine. 2018. DOI: 10.1002/lsm.23005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.