DOI 10.1080/13506129.2018.1520087
Quantitation of 99mTc-DPD uptake in patients with transthyretin-related cardiac amyloidosis.
Аннотация
PURPOSE: Transthyretin (ATTR) amyloidosis is a rare but serious infiltrative disease associated with a wide spectrum of morphologic and functional cardiac involvement. 99mTc-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD), initially developed as a bone-seeking radiotracer, is remarkably sensitive for imaging cardiac ATTR amyloid deposits. Our aim was to investigate the feasibility and utility of estimating 99mTc-DPD uptake in myocardial tissue; this has the potential to yield reliable quantitative information on cardiac amyloid burden, which is urgently required to monitor disease progression and response to novel treatments.
METHODS
Three methods of quantitation were developed and tested on 74 patients with proven cardiac ATTR amyloidosis who had recently undergone 99mTc-DPD planar whole-body imaging and SPECT-CT. Quantitative results were compared to measurements of extracellular volume fraction (ECV) by cardiac magnetic resonance imaging, a validated technique for measuring amyloid burden.
RESULTS
An experienced clinician graded uptake using a widely-used visual scoring system as 1 (n = 15), 2 (n = 39) or 3 (n = 20). Linear correlations between the SPECT and ECV data (p < .001) were demonstrated. None of the methods showed that 99mTc-DPD uptake in the heart was significantly greater in patients with grade-3 uptake than in those with grade-2 uptake.
CONCLUSIONS
Quantitation of 99mTc-DPD uptake in cardiac transthyretin amyloid deposits is complex and is hindered by competition for radiotracer with amyloid in skeletal muscle. The latter underlies differences in uptake between grade-2 and grade-3 patients, not cardiac uptake.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.