Pediatric dentistry · 2007
Laboratory-made space maintainers: a 7-year retrospective study from private pediatric dental practice.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fathian Mehrdad, Kennedy David B, Nouri M Reza
Аннотация
PURPOSE: The purpose of this study was to report survival times and problems encountered with laboratory made space maintainers placed over 7 years by one pediatric dentist.
METHODS: Charts were reviewed for 235 patients with fixed space maintainers placed between January 1, 1997, and December 31, 2003, and followed to December 31, 2005. Problems encountered and appliance lifetimes were recorded and assessed. Failures were recorded as: (1) cement loss; (2) solder breakage; (3) split bands; (4) eruption interference; (5) bent wire; (6) complete loss; or (7) not specified. Appliance outcomes, transferred patients, and those lost to follow-up were recorded.
RESULTS: A total of 323 appliances were followed, with: (a) 93 (29%) successes; (b) 110 (34%) still in service; and (c) 104 (32%) known failures. Of the latter, most (62%) were from cement loss (60%) and 13 (12%) were totally lost. No statistically significant differences were noted between types of appliances, gender, and types of failure, except for the fact that bands and loops exhibited more cement loss (P=.045). Mean pooled survival times were between 26 and 27 months.. Of the 104 failures: (a) 34 (33%) were no longer needed (being considered clinically successful); (b) 57 (55%) were recemented; and (c) 13 (12%) were remade. Sixteen appliances were lost to follow-up or transferred.
CONCLUSION: A total of 63% of all space maintainers lasted their anticipated lifetimes or were still in use.
METHODS: Charts were reviewed for 235 patients with fixed space maintainers placed between January 1, 1997, and December 31, 2003, and followed to December 31, 2005. Problems encountered and appliance lifetimes were recorded and assessed. Failures were recorded as: (1) cement loss; (2) solder breakage; (3) split bands; (4) eruption interference; (5) bent wire; (6) complete loss; or (7) not specified. Appliance outcomes, transferred patients, and those lost to follow-up were recorded.
RESULTS: A total of 323 appliances were followed, with: (a) 93 (29%) successes; (b) 110 (34%) still in service; and (c) 104 (32%) known failures. Of the latter, most (62%) were from cement loss (60%) and 13 (12%) were totally lost. No statistically significant differences were noted between types of appliances, gender, and types of failure, except for the fact that bands and loops exhibited more cement loss (P=.045). Mean pooled survival times were between 26 and 27 months.. Of the 104 failures: (a) 34 (33%) were no longer needed (being considered clinically successful); (b) 57 (55%) were recemented; and (c) 13 (12%) were remade. Sixteen appliances were lost to follow-up or transferred.
CONCLUSION: A total of 63% of all space maintainers lasted their anticipated lifetimes or were still in use.