MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000001963

Медицинская библиотека · Nuclear medicine communications · 2025

Interpretation of basal nuclei in brain dopamine transporter scans using a deep convolutional neural network.

Chen Hsin-Yung, Tsai Ya-Ju, Peng Syu-Jyun

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Functional imaging using the dopamine transporter (DAT) as a biomarker has proven effective in assessing dopaminergic neuron degeneration in the striatum. In assessing the neuron degeneration, visual and semiquantitative methods are used to interpret DAT single-photon emission tomography (SPECT) scans based on striatal to background activity, striatal shape, and symmetry. Visual analysis, however, is subjective and reviewer dependent, whereas semiquantitative methods are operator dependent. Our goal in the current study was to derive results via deep learning to facilitate the clinical diagnosis of Parkinson's disease (PD).

METHODS

This retrospective study collected data from 416 patients with clinically uncertain Parkinsonian syndrome who underwent DAT SPECT via 99m Tc-TRODAT-1 ([2-[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]oct-2-yl]methyl](2-mercaptoethyl)amino]ethyl]amino]ethanethiolato (3-)- N2,N2',S2,S2' ]oxo-[1 R -( exo - exo )]). Transfer learning was used to estimate the degree of dopaminergic neuron degeneration in the caudate and putamen for use in classifying images according to stage. Three pretrained models - Xception, InceptionV3, and ResNet101 - were retrained and tested after undergoing transfer learning for the classification of striatum dopaminergic neuron degeneration.

RESULTS

Overall, the performance of Xception exceeded that of InceptionV3 and ResNet101. The accuracy, macro F1 score, and kappa value of the proposed caudate classification model were 81.93%, 0.70, and 0.64, respectively. The accuracy, macro F1 score, and kappa value of the proposed putamen classification model were 88.75%, 0.64, and 0.61, respectively.

CONCLUSION

The proposed deep convolutional neural network provided a good model by which to interpret DAT SPECT of basal nuclei. We believe that the model could be used as an auxiliary tool to facilitate image interpretation and enhance accuracy in the diagnosis of PD.

Для цитирования: Chen Hsin-Yung, Tsai Ya-Ju, Peng Syu-Jyun. Interpretation of basal nuclei in brain dopamine transporter scans using a deep convolutional neural network.. Nuclear medicine communications. 2025. DOI: 10.1097/mnm.0000000000001963.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.