MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.64.11.16

Медицинская библиотека · Investigative ophthalmology & visual science · 2023

Relationship Between Suppression Scotomas and Stereoacuity in Anisometropic Amblyopia With Successfully Treated Visual Acuity.

Hozumi Kenta, Yagasaki Teiji, Yokoyama Yoshimi, Yagasaki Ayaka, Haga Yayoi, Eboshita Riho

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to investigate the relationship among suppression scotoma size, stereoacuity, and four-prism base-out test (4ΔBOT) results in anisometropic amblyopia with successfully treated visual acuity.

METHODS

We included 103 cases of anisometropic amblyopia successfully treated for visual acuity without strabismus. Stereoacuity was measured using a Randot Stereotest. The size of the suppression scotomas was measured using a new device, the polarized four dot (P4D) test. This is a modification of the Worth 4 dot test (W4D) device. The patients were divided into three groups based on the 4ΔBOT results: normal (group A = 29 cases), subnormal (group B = 48 cases), and abnormal (group C = 26 cases) response groups. The horizontal diameter of the suppression scotomas and stereoacuity in logarithmic values with a base of 20 seconds of arc (″) were compared among the 3 groups.

RESULTS

The mean age at P4D testing was 8.4 ± 2.1 years. The average horizontal diameters of the suppression scotomas were 0.35 ± 0.79Δ, 2.01 ± 0.82Δ, and 5.50 ± 2.72Δ in groups A, B, and C, respectively, showing significant differences (A versus B: P < 0.0001, A versus C: P < 0.0001, and B versus C: P < 0.0001; 1-way ANOVA). The average logarithmic stereoacuity were 1.07 (24.95″), 1.22 (38.84″), and 1.47 (82.79″) in groups A, B, and C, respectively, thereby showing significant differences between the groups (A versus B: P < 0.0001, A versus C: P < 0.0001, and B versus C: P < 0.0001; 1-way ANOVA). Stereoacuity and horizontal diameter of the suppression scotoma were strongly correlated (r = 0.732, P < 0.0001).

CONCLUSIONS

The suppression scotoma size measured using P4D correlated significantly with stereoacuity and the 4ΔBOT results.

Для цитирования: Hozumi Kenta, Yagasaki Teiji, Yokoyama Yoshimi, Yagasaki Ayaka, Haga Yayoi, Eboshita Riho. Relationship Between Suppression Scotomas and Stereoacuity in Anisometropic Amblyopia With Successfully Treated Visual Acuity.. Investigative ophthalmology & visual science. 2023. DOI: 10.1167/iovs.64.11.16.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.