MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2015.06.066

Медицинская библиотека · Annals of vascular surgery · 2015

A New Hemodynamic Ex Vivo Model for Medical Devices Assessment.

Maurel Blandine, Sarraf Christophe, Bakir Farid, Chai Feng, Maton Mickael, Sobocinski Jonathan, Hertault Adrien, Blanchemain Nicolas, Haulon Stephan, Lermusiaux Patrick

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

In-stent restenosis (ISR) remains a major public health concern associated with an increased morbidity, mortality, and health-related costs. Drug-eluting stents (DES) have reduced ISR, but generate healing-related issues or hypersensitivity reactions, leading to an increased risk of late acute stent thrombosis. Assessments of new DES are based on animal models or in vitro release systems, which have several limitations. The role of flow and shear stress on endothelial cell and ISR has also been emphasized. The aim of this work was to design and first evaluate an original bioreactor, replicating ex vivo hemodynamic and biological conditions similar to human conditions, to further evaluate new DES.

METHODS

This bioreactor was designed to study up to 6 stented arteries connected in bypass, immersed in a culture box, in which circulated a physiological systolo-diastolic resistive flow. Two centrifugal pumps drove the flow. The main pump generated pulsating flows by modulation of rotation velocity, and the second pump worked at constant rotation velocity, ensuring the counter pressure levels and backflows. The flow rate, the velocity profile, the arterial pressure, and the resistance of the flow were adjustable. The bioreactor was placed in an incubator to reproduce a biological environment.

RESULTS

A first feasibility experience was performed over a 24-day period. Three rat aortic thoracic arteries were placed into the bioreactor, immersed in cell culture medium changed every 3 days, and with a circulating systolic and diastolic flux during the entire experimentation. There was no infection and no leak. At the end of the experimentation, a morphometric analysis was performed confirming the viability of the arteries.

CONCLUSIONS

We designed and patented an original hemodynamic ex vivo model to further study new DES, as well as a wide range of vascular diseases and medical devices. This bioreactor will allow characterization of the velocity field and drug transfers within a stented artery with new functionalized DES, with experimental means not available in vivo. Another major benefit will be the reduction of animal experimentation and the opportunity to test new DES or other vascular therapeutics in human tissues (human infrapopliteal or coronary arteries collected during human donation).

Для цитирования: Maurel Blandine, Sarraf Christophe, Bakir Farid, Chai Feng, Maton Mickael, Sobocinski Jonathan, Hertault Adrien, Blanchemain Nicolas, Haulon Stephan, Lermusiaux Patrick. A New Hemodynamic Ex Vivo Model for Medical Devices Assessment.. Annals of vascular surgery. 2015. DOI: 10.1016/j.avsg.2015.06.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.