DOI 10.1097/mao.0b013e31818de5b3
Eustachian tube function and habitual sniffing in middle ear cholesteatoma.
Аннотация
OBJECTIVE
To investigate the incidence of habitual sniffing and the function of eustachian tube in middle ear cholesteatoma.
STUDY
DESIGN
Prospective study.
SETTING
University hospital.
PATIENTS: One hundred thirteen consecutive cases of primary acquired cholesteatoma were operated on from July 2005 to December 2007, and they consisted of 78 pars flaccida type (69.9%), 25 pars tensa type (22.1%), and 10 unclassified large type (8.8%). As a comparison, 178 consecutive cases of chronic otitis media (COM) and 30 consecutive cases of otosclerosis were also examined.
METHODS
A questionnaire was administered regarding symptoms of patulous tube and habitual sniffing to alleviate ear symptoms. Eustachian tube function was examined by sonotubometry.
RESULTS
The eustachian tube function in cholesteatoma showed patulous type (25.7%), stenotic type (44.2%), and normal type (30.1%), whereas that in COM showed 11.2%, 25.3%, and 63.5%, respectively, and that in otosclerosis showed 6.7%, 16.6%, and 76.7%, respectively. The incidence of patulous type is significantly higher in cholesteatoma than in COM (p < 0.01) and in otosclerosis (p < 0.05). Habitual sniffing was found to be significantly higher in cholesteatoma (31/113, 27.4%) than in COM (9/178, 5.1%) (p < 0.001) and in otosclerosis (1/30, 3.3%) (p < 0.001). The existence of diseases on the contralateral side was significantly higher in cases with habitual sniffing (26/31, 83.9%) than in those without habitual sniffing (32/82, 39.0%) (p < 0.001). After the canal wall up method, postoperative retraction of the eardrum is significantly related to habitual sniffing continuing after the surgery.
CONCLUSION
Patulous eustachian tube and habitual sniffing may play a role for pathogenesis of middle ear cholesteatoma.