Smartphone-based analytical platform for real-time, reversible detection of Co2+, Ni2+, Cu2+, and Zn2+ ions.

Kaur Manpreet, Virender Virender, Singh Jasbir, Kumar Ashwani, Dubey Santosh Kumar

СтатьяОценочное исследованиеПеревод пока не подготовлен

Аннотация

This study explores the new Schiff base ligand, (Z)-N'-(1-(2-hydroxy-5-methoxyphenyl)ethylidene)-3-methoxybenzohydrazide (L), as a portable and selective sensor for the detection of Co2+, Ni2+, Cu2+, and Zn2+ ions. We hypothesized that L could enable real-time, reversible metal ion sensing via optical changes and suitable for smartphone-based analysis. The metal-ligand interactions were studied using UV-Vis, fluorescence, cyclic voltammetry, and NMR techniques. The ligand formed a 1:1 complex with good binding affinities and low detection limits. A colorimetric naked eye change and fluorescence responses allowed visual detection and quantitative analysis via RGB values evaluated by a smartphone application. The sensing process was reversible with Na2EDTA and effective in the neutral pH range. The sensor was successfully applied to spiked water samples and germinated seeds. These results confirm the initial hypothesis and highlight the potential of L as a low-cost, effective tool for monitoring these ions for food quality assessment, environmental safety, and medical applications.

Для цитирования: Kaur Manpreet, Virender Virender, Singh Jasbir, Kumar Ashwani, Dubey Santosh Kumar. Smartphone-based analytical platform for real-time, reversible detection of Co2+, Ni2+, Cu2+, and Zn2+ ions.. Food chemistry. 2025. DOI: 10.1016/j.foodchem.2025.145388.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.