MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1103/physreve.69.031919

Медицинская библиотека · Physical review. E, Statistical, nonlinear, and soft matter physics · 2004

Lattice Boltzmann simulation on particle suspensions in a two-dimensional symmetric stenotic artery.

Li Huabing, Fang Haiping, Lin Zhifang, Xu ShiXiong, Chen Shiyi

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The technique of lattice Boltzmann simulation has been applied to the study of two-dimensional particle suspensions through a modeled arterial stenosis. The stenosis model consists of two-side symmetric semicirculars in a planar channel with the width of the stenosis throat larger than d and less than 2d, where d is the diameter of the particles. When only one particle is positioned off-centerline initially, the particle migrates off-centerline after passing the stenosis and the velocity at the stenosis throat is much larger than that in a flat tube. Only when two particles are positioned symmetrically to the centerline to a very high accuracy can the flow be blocked by two particles completely. A very small asymmetry will be amplified proximal to the stenosis throat in that one of the particles goes back to leave space to let the other particle passing the stenosis first so that the particles cannot be blocked. An evidence of attractive interactions between the particles as well as a particle and a proximal protuberance is observed when the asymmetry is very small and the width at the stenosis throat is between two critical values. The hematocrit distribution of the particles is studied by simulating multiparticle suspensions. It is found that the width of the stenosis throat has a significant influence on the hematocrit distribution of the particles in the flat tubes far from the stenosis.

Для цитирования: Li Huabing, Fang Haiping, Lin Zhifang, Xu ShiXiong, Chen Shiyi. Lattice Boltzmann simulation on particle suspensions in a two-dimensional symmetric stenotic artery.. Physical review. E, Statistical, nonlinear, and soft matter physics. 2004. DOI: 10.1103/physreve.69.031919.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.