MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001504

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2022

Does Cardiac Catheterization Facilitate Hemodynamic Optimization of Pediatric Patients on Continuous-Flow Ventricular Assist Devices?

Lahiri Subhrajit, Choudhry Swati, Denfield Susan W, Price Jack F, Cabrera Antonio G, Dreyer William J, Spinner Joseph A, Loar Robert W, Elias Barb, McMullen Jason, Qureshi Athar M, Adachi Iki, Tunuguntla Hari Priya

СтатьяПеревод пока не подготовлен

Аннотация

Understanding optimal ventricular assist device (VAD) parameters for pediatric patients is valuable given the inherent issue of patient-device size mismatch and heterogeneous cardiac anatomy in children. We evaluated our center's experience of continuous-flow VAD (CF-VAD) optimization using cardiac catheterization. We performed a retrospective analysis of all patients on CF-VAD support who underwent hemodynamic heart catheterization from 2013 to 2018. Fifteen patients had 16 hemodynamic catheterizations performed. The indications for hemodynamic optimization by catheterization included clinical signs of heart failure while on CF-VAD (9 of 16, 56%), pretransplant evaluation of pulmonary hypertension (2 of 16, 13%), or assessment of myocardial recovery (5 of 16, 31%). The median age at catheterization was 12 years (interquartile range: 8-16). Median baseline speed of device was 2333 ± 253 rotations per minute. The goal was to find the speed at which optimal hemodynamics were achieved, defined by low wedge pressure with an acceptable central venous pressure. Of the 16 catheterizations, there were 9 (56%) speed increases to achieve optimal hemodynamics and 5 (33%) speed decreases for hemodynamic optimization or for potential explant. The speed was not changed in 2 (13%) catheterizations as the patients were determined to be at an optimal hemodynamic state. Overall, VAD settings were optimized in 75% (14 of 16) of hemodynamic catheterizations. There were no adverse events related to catheterization. Thus, we conclude that catheterization-based hemodynamic assessment is safe and effective for optimizing VAD speed and provides guidance on medical management in children supported on CF-VAD.

Для цитирования: Lahiri Subhrajit, Choudhry Swati, Denfield Susan W, Price Jack F, Cabrera Antonio G, Dreyer William J, Spinner Joseph A, Loar Robert W, Elias Barb, McMullen Jason, Qureshi Athar M, Adachi Iki, Tunuguntla Hari Priya. Does Cardiac Catheterization Facilitate Hemodynamic Optimization of Pediatric Patients on Continuous-Flow Ventricular Assist Devices?. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2022. DOI: 10.1097/mat.0000000000001504.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.