m+Medelevator.RU
← Поиск публикаций
Journal of imaging informatics in medicine · 2024

A Pilot Clinical and Technical Validation of an Immersive Virtual Reality Platform for 3D Anatomical Modeling and Contouring in Support of Surgical and Radiation Oncology Treatment Planning.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Belec Jason, Sutherland Justin, Volpini Matthew, Rakhra Kawan, Granville Dal, La Russa Dan, Flaxman Teresa, De Oliveira Eduardo Portela, Glikstein Rafael, Dos Santos Marlise P, Werier Joel, MacPherson Miller, Aviv Richard I, Nair Vimoj

Аннотация

The aim of this study was to validate a novel medical virtual reality (VR) platform used for medical image segmentation and contouring in radiation oncology and 3D anatomical modeling and simulation for planning medical interventions, including surgery. The first step of the validation was to verify quantitatively and qualitatively that the VR platform can produce substantially equivalent 3D anatomical models, image contours, and measurements to those generated with existing commercial platforms. To achieve this, a total of eight image sets and 18 structures were segmented using both VR and reference commercial platforms. The image sets were chosen to cover a broad range of scanner manufacturers, modalities, and voxel dimensions. The second step consisted of evaluating whether the VR platform could provide efficiency improvements for target delineation in radiation oncology planning. To assess this, the image sets for five pediatric patients with resected standard-risk medulloblastoma were used to contour target volumes in support of treatment planning of craniospinal irradiation, requiring complete inclusion of the entire cerebral-spinal volume. Structures generated in the VR and the commercial platforms were found to have a high degree of similarity, with dice similarity coefficient ranging from 0.963 to 0.985 for high-resolution images and 0.920 to 0.990 for lower resolution images. Volume, cross-sectional area, and length measurements were also found to be in agreement with reference values derived from a commercial system, with length measurements having a maximum difference of 0.22 mm, angle measurements having a maximum difference of 0.04°, and cross-sectional area measurements having a maximum difference of 0.16 mm2. The VR platform was also found to yield significant efficiency improvements, reducing the time required to delineate complex cranial and spinal target volumes by an average of 50% or 29 min.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты