MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12194-024-00809-7

Медицинская библиотека · Radiological physics and technology · 2024

Dosimetric effects of small field size, dose grid size, and variable split-arc methods on gamma pass rates in radiation therapy.

Kuwae Tsunekazu, Ariga Takuro, Kusada Takeaki, Nishie Akihiro

СтатьяПеревод пока не подготовлен

Аннотация

This study investigates the influence of calculation accuracy in peripheral low-dose regions on the gamma pass rate (GPR), utilizing the Acuros XB (AXB) algorithm and ArcCHECK™ measurement. The effects of varying small field sizes, dose grid sizes, and split-arc techniques on GPR were analyzed. Various small field sizes were employed. Thirty-two single-arc plans with dose grid sizes of 2 mm and 1 mm and prescribed doses of 2, 5, 10, and 20 Gy were calculated using the AXB algorithm. In total, 128 GPR plans were examined. These plans were categorized into three sub-fields (3SF), four sub-fields (4SF), and six sub-fields (6SF). The GPR results deteriorated with smaller target sizes and a 2 mm dose grid size in a single arc. A similar degradation in GPR was observed with smaller target sizes and a 1 mm dose grid size. However, the 1 mm dose grid size generally resulted in better GPR compared with the 2 mm dose grid size for the same target sizes. The GPR improved with finer split angles and a 2 mm dose grid size in the split-arc method. However, no statistically significant improvement was observed with finer split angles and a 1 mm dose grid size. This study demonstrates that coarser dose grid sizes result in lower GPRs in peripheral low-dose regions as calculated by AXB with ArcCHECK™ measurement. To enhance GPR, employing split-arc methods and finer dose grid sizes could be beneficial.

Для цитирования: Kuwae Tsunekazu, Ariga Takuro, Kusada Takeaki, Nishie Akihiro. Dosimetric effects of small field size, dose grid size, and variable split-arc methods on gamma pass rates in radiation therapy.. Radiological physics and technology. 2024. DOI: 10.1007/s12194-024-00809-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.