Intra-fractional dose rate effect in continuous and interrupted irradiation of the MCF-7 cell line: Possible radiobiological implications for breath-hold techniques in breast radiotherapy?

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mosleh-Shirazi Mohammad Amin, Kazempour Somayeh, Fardid Reza, Sharifzadeh Sedigheh, Karbasi Sareh

Аннотация

PURPOSE: To investigate the effects of different dose rates (DRs) in continuous and interrupted irradiation on in-vitro survival of the MCF-7 cell line, towards finding possible radiobiological effects of breath-hold techniques in breast radiotherapy (RT), in which intra-fractional beam interruptions and delivery prolongation can occur.

MATERIALS AND METHODS: MCF-7 cells were irradiated continuously or with regular interruptions using 6 MV x-rays at different accelerator DRs (50-400 cGy/min) to deliver a 2 Gy dose. The interrupted irradiation was delivered in a 10 s on, 10 s off manner. Then, cell survival and viability were studied using colony and MTT assays, respectively.

RESULTS: Survival and viability with continuous and interrupted irradiation were similar ( P > 0.5). A significant increase in survival at 50, 100, and 400 cGy/min compared to 200 and 300 cGy/min was observed, also a significant decreasing and then increasing trend from 50 to 200 cGy/min and 200 to 400 cGy/min, respectively ( P < 0.04). Relative to 200 cGy/min, the survival fractions at 50, 100, 300, and 400 cGy/min were 1.24, 1.23, 1.05, and 1.20 times greater, respectively. Cell viability did not show significant differences between the DRs, despite following the same trend as cell survival.

CONCLUSION: Our results suggest that for continuous irradiation of in-vitro MCF-7 cells, with increasing DR within the 50-400 cGy/min range, sensitivity increases and then decreases (inverse effect), also that up to doubling of treatment time in breath-hold techniques does not affect in-vitro radiobiological efficacy with 200-400 cGy/min accelerator DRs. Further confirmatory studies are required.