Intra-fractional dose rate effect in continuous and interrupted irradiation of the MCF-7 cell line: Possible radiobiological implications for breath-hold techniques in breast radiotherapy?

Mosleh-Shirazi Mohammad Amin, Kazempour Somayeh, Fardid Reza, Sharifzadeh Sedigheh, Karbasi Sareh

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the effects of different dose rates (DRs) in continuous and interrupted irradiation on in-vitro survival of the MCF-7 cell line, towards finding possible radiobiological effects of breath-hold techniques in breast radiotherapy (RT), in which intra-fractional beam interruptions and delivery prolongation can occur.

MATERIALS AND

METHODS

MCF-7 cells were irradiated continuously or with regular interruptions using 6 MV x-rays at different accelerator DRs (50-400 cGy/min) to deliver a 2 Gy dose. The interrupted irradiation was delivered in a 10 s on, 10 s off manner. Then, cell survival and viability were studied using colony and MTT assays, respectively.

RESULTS

Survival and viability with continuous and interrupted irradiation were similar ( P > 0.5). A significant increase in survival at 50, 100, and 400 cGy/min compared to 200 and 300 cGy/min was observed, also a significant decreasing and then increasing trend from 50 to 200 cGy/min and 200 to 400 cGy/min, respectively ( P < 0.04). Relative to 200 cGy/min, the survival fractions at 50, 100, 300, and 400 cGy/min were 1.24, 1.23, 1.05, and 1.20 times greater, respectively. Cell viability did not show significant differences between the DRs, despite following the same trend as cell survival.

CONCLUSION

Our results suggest that for continuous irradiation of in-vitro MCF-7 cells, with increasing DR within the 50-400 cGy/min range, sensitivity increases and then decreases (inverse effect), also that up to doubling of treatment time in breath-hold techniques does not affect in-vitro radiobiological efficacy with 200-400 cGy/min accelerator DRs. Further confirmatory studies are required.

Для цитирования: Mosleh-Shirazi Mohammad Amin, Kazempour Somayeh, Fardid Reza, Sharifzadeh Sedigheh, Karbasi Sareh. Intra-fractional dose rate effect in continuous and interrupted irradiation of the MCF-7 cell line: Possible radiobiological implications for breath-hold techniques in breast radiotherapy?. Journal of cancer research and therapeutics. 2024. DOI: 10.4103/jcrt.jcrt_826_21.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.