DOI 10.1016/j.jcct.2017.02.006

Медицинская библиотека · Journal of cardiovascular computed tomography · 2017

Automatic quantification of the myocardial extracellular volume by cardiac computed tomography: Synthetic ECV by CCT.

Treibel Thomas A, Fontana Marianna, Steeden Jennifer A, Nasis Arthur, Yeung Jason, White Steven K, Sivarajan Sri, Punwani Shonit, Pugliese Francesca, Taylor Stuart A, Moon James C, Bandula Steve

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The quantification of extracellular volume fraction (ECV) by Cardiac Computed Tomography (CCT) can identify changes in the myocardial interstitium due to fibrosis or infiltration. Current methodologies require laboratory blood hematocrit (Hct) measurement - which complicates the technique. The attenuation of blood (HUblood) is known to change with anemia. We hypothesized that the relationship between Hct and HUblood could be calibrated to rapidly generate a synthetic ECV without formally measuring Hct.

METHODS

The association between Hct and HUblood was derived from forty non-contrast thoracic CT scans using regression analysis. Synthetic Hct was then used to calculate synthetic ECV, and in turn compared with ECV using blood Hct in a validation cohort with mild interstitial expansion due to fibrosis (aortic stenosis, n = 28, ECVCT = 28 ± 4%) and severe interstitial expansion due to amyloidosis (n = 27; ECVCT = 54 ± 11%, p < 0.001). For histological validation, synthetic ECV was correlated with collagen volume fraction (CVF) in a separate cohort with aortic stenosis (n = 18). All CT scans were performed at 120 kV and 160 mAs.

RESULTS

HUblood was a good predictor of Hct (R2 = 0.47; p < 0.01), with the regression model (Hct = [0.51 * HUblood] + 17.4) describing the association. Synthetic ECV correlated well with conventional ECV (R2 = 0.96; p < 0.01) with minimal bias and 2SD difference of 5.7%. Synthetic ECV correlated as well as conventional ECV with histological CVF (both R2 = 0.50, p < 0.01). Finally, we implemented an automatic ECV plug-in for offline analysis.

CONCLUSION

Synthetic ECV by CCT provides instantaneous quantification of the myocardial extracellular space without the need for blood sampling.

Для цитирования: Treibel Thomas A, Fontana Marianna, Steeden Jennifer A, Nasis Arthur, Yeung Jason, White Steven K, Sivarajan Sri, Punwani Shonit, Pugliese Francesca, Taylor Stuart A, Moon James C, Bandula Steve. Automatic quantification of the myocardial extracellular volume by cardiac computed tomography: Synthetic ECV by CCT.. Journal of cardiovascular computed tomography. 2017. DOI: 10.1016/j.jcct.2017.02.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.