m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2014

From bare to covered: 15-year single center experience and follow-up in trans-catheter stent implantation for aortic coarctation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Butera Gianfranco, Manica João Luiz Langer, Marini Davide, Piazza Luciane, Chessa Massimo, Filho Raul Ivo Rossi, Sarmento Leite Rogério E, Carminati Mario

Аннотация

BACKGROUND: Bare stents has become the first line therapy for aortic coarctation. Covered stents has been reported more recently in clinical practice.

OBJECTIVES: The present study, reports comparatively 15-year experience of bare and covered stent implantation for aortic coarctation in a single tertiary referral center.

METHODS: From 1997 to 2011, 143 patients with native or postoperative aortic coarctation were treated at our institution. Seventy-one subjects (median age 17 years (range from 4 to 70 years) underwent bare stent implantation (Group 1) while 72 patients (median age of 17.5 years (range from 6 to 68 years) underwent covered stent implantation (Group 2).

RESULTS: Success rate in the whole group was 95%. More complex and tighter coarctations were treated using covered stents. Incidence of related-procedure adverse events was higher in Group 1 than in group 2 (21.1% vs. 8.3% P = 0.035). Aortic wall complications occurred in 7% of patients in Group 1 (one death) and 0% in Group 2 (P = 0.028). Subjects in Group 1 had a longer follow-up (median 85 vs. 35 months; P < 0.001). Independent predictors associated with reintervention included the presence of complex lesions (HR: 2.70; CI: 1.15-6.32), balloon diameter used <14 mm (HR: 3.76; CI: 1.48-9.55), and immediate residual gradient >10 mm Hg (HR: 4.30; CI: 1.96-9.47).

CONCLUSIONS: Both bare and covered stent implantation for aortic coarctation is a safe and efficacious treatment. By using covered stent implantation the spectrum of patients treated has increased with lower rates of acute and late complications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты