MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2012.10.023

Медицинская библиотека · Annals of vascular surgery · 2013

Incidence and complications of accidental cannulation of retroperitoneal veins during venography for inferior vena cava filter placement.

Gill Gunvir, Morita Satoru, Kitanosono Takashi, Fang Adam, Lee David, Waldman David

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this study was to evaluate the incidence and complications of accidental cannulation of retroperitoneal veins during venography for inferior vena cava (IVC) filter placement.

METHODS

In total, 641 patients who underwent IVC filter placement were retrospectively reviewed. Incidence of accidental cannulation of retroperitoneal veins during venography (using 633 sheaths and 18 catheters, including 11 pigtail type and 7 end-hole-type catheters), along with the associated complications, were evaluated.

RESULTS

The overall frequency of accidental cannulation of retroperitoneal veins was 5.4% (35 of 651) via venous approaches: 5.8% (24 of 411) via a right femoral approach, 3.9% (5 of 129) via a left femoral approach, and 5.4% (6 of 111) via a jugular approach. The most frequent veins cannulated were the ascending lumbar veins (4.6%, 25 of 540) via a femoral approach, and the median sacral vein (3.6%, 4 of 111) via a jugular approach. No significant difference in the frequency of accidental cannulation was observed between venography through sheaths and catheters (5.4% [n = 34] vs. 5.6% [n = 1; using an end-hole-type catheter]; P = 1.000). Injuries to 5 veins (0.8%), including 3 ascending lumbar veins, were observed. Inadvertent filter placement within the right ascending lumbar vein was observed in 1 patient (0.2%).

CONCLUSIONS

Accidental cannulation of retroperitoneal veins during venography for IVC filter placement is an infrequent occurrence, and in this patient series did not result in negative clinical outcomes. However, operators should be aware of the risk of accidental cannulation to prevent avoidable complications such as venous injury or filter misplacement.

Для цитирования: Gill Gunvir, Morita Satoru, Kitanosono Takashi, Fang Adam, Lee David, Waldman David. Incidence and complications of accidental cannulation of retroperitoneal veins during venography for inferior vena cava filter placement.. Annals of vascular surgery. 2013. DOI: 10.1016/j.avsg.2012.10.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.