Factors influencing the performance of rapid SARS-CoV-2 antigen tests under field condition.

Begum Mst Noorjahan, Jubair Mohammad, Nahar Kamrun, Rahman Sezanur, Talha Muhammad, Sarker Md Safiullah, Uddin A K M Nasir, Khaled Saifuddin, Uddin Mohammed Shehab, Li Zhibiao, Ke Tianlin, Rahman Mohammed Ziaur, Rahman Mustafizur

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Globally, real-time reverse transcription-polymerase chain reaction (rRT-PCR) is the reference detection technique for SARS-CoV-2, which is expensive, time consuming, and requires trained laboratory personnel. Thus, a cost-effective, rapid antigen test is urgently needed. This study evaluated the performance of the rapid antigen tests (RATs) for SARS-CoV-2 compared with rRT-PCR, considering different influencing factors.

METHODS

We enrolled a total of 214 symptomatic individuals with known COVID-19 status using rRT-PCR. We collected and tested paired nasopharyngeal (NP) and nasal swab (NS) specimens (collected from same individual) using rRT-PCR and RATs (InTec and SD Biosensor). We assessed the performance of RATs considering specimen types, viral load, the onset of symptoms, and presenting symptoms.

RESULTS

We included 214 paired specimens (112 NP and 100 NS SARS-CoV-2 rRT-PCR positive) to the analysis. For NP specimens, the average sensitivity, specificity, and accuracy of the RATs were 87.5%, 98.6%, and 92.8%, respectively, when compared with rRT-PCR. While for NS, the overall kit performance was slightly lower than that of NP (sensitivity 79.0%, specificity 96.1%, and accuracy 88.3%). We observed a progressive decline in the performance of RATs with increased Ct values (decreased viral load). Moreover, the RAT sensitivity using NP specimens decreased over the time of the onset of symptoms.

CONCLUSION

The RATs showed strong performance under field conditions and fulfilled the minimum performance limit for rapid antigen detection kits recommended by World Health Organization. The best performance of the RATs can be achieved within the first week of the onset of symptoms with high viral load.

Для цитирования: Begum Mst Noorjahan, Jubair Mohammad, Nahar Kamrun, Rahman Sezanur, Talha Muhammad, Sarker Md Safiullah, Uddin A K M Nasir, Khaled Saifuddin, Uddin Mohammed Shehab, Li Zhibiao, Ke Tianlin, Rahman Mohammed Ziaur, Rahman Mustafizur. Factors influencing the performance of rapid SARS-CoV-2 antigen tests under field condition.. Journal of clinical laboratory analysis. 2021. DOI: 10.1002/jcla.24203.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.