Laferl Hermann, Seitz Tamara, Baier-Grabner Sebastian, Kelani Hasan, Scholz Elisabeth, Heger Florian, Götzinger Florian, Frischer Prof Thomas, Wenisch Christoph, Allerberger Prof Franz
Аннотация
BACKGROUND: The use of nasopharyngeal (NP) swabs as a specimen collection method to diagnose SARS-CoV-2 infection is frequently perceived as uncomfortable by patients and requires trained personnel. In this study, detection rate of SARS-CoV-2 in mouthwash samples and buccal swabs were compared in both children and adults.
MATERIAL AND METHODS: In patients admitted to hospital with confirmed COVID-19 within the previous 72 hours, NP and buccal swabs as well as mouthwash samples were collected. RT-qPCR was performed on all samples.
RESULTS: In total, 170 samples were collected from 155 patients (137 adults and 18 children). Approximately 91.7% of the collected NP swabs were positive in RT-PCR compared to 63.1% of mouthwash samples and 42.4% of buccal swabs. Compared to NP swabs, the sensitivity of using mouthwash was 96.3% and 65.4% for buccal swabs in NP swab samples with a CT value <25. With increasing CT values, sensitivity decreased in both mouthwash and buccal swabs. The virus load was highest during the first week of infection, with a continuous decline observed in all three collection methods over time.
DISCUSSION: Mouthwash presents an alternative collection method for detecting SARS-CoV-2 in the case of unfeasible NP swab sampling. Buccal swabs should not be used due to their low sensitivity.
MATERIAL AND METHODS: In patients admitted to hospital with confirmed COVID-19 within the previous 72 hours, NP and buccal swabs as well as mouthwash samples were collected. RT-qPCR was performed on all samples.
RESULTS: In total, 170 samples were collected from 155 patients (137 adults and 18 children). Approximately 91.7% of the collected NP swabs were positive in RT-PCR compared to 63.1% of mouthwash samples and 42.4% of buccal swabs. Compared to NP swabs, the sensitivity of using mouthwash was 96.3% and 65.4% for buccal swabs in NP swab samples with a CT value <25. With increasing CT values, sensitivity decreased in both mouthwash and buccal swabs. The virus load was highest during the first week of infection, with a continuous decline observed in all three collection methods over time.
DISCUSSION: Mouthwash presents an alternative collection method for detecting SARS-CoV-2 in the case of unfeasible NP swab sampling. Buccal swabs should not be used due to their low sensitivity.