Abnormalities of somatosensory evoked potentials in konzo--an upper motor neuron disorder.

Tshala-Katumbay D, Edebol Eeg-Olofsson K, Kazadi-Kayembe T, Fällmar Peo, Tylleskär Thorkild, Kayembe-Kalula T

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine whether the somatosensory pathways are involved or not in konzo.

METHODS

In 1998, 21 konzo subjects (15 females and 6 males; mean age 21 years) underwent a SEP study with a two-channel-equipment (Medtronic Keypoint, Denmark) whereas in 2000, 15 subjects (7 females and 8 males; mean age 21 years) participated in a study with a 4-channel-equipment.

RESULTS

Most subjects (19/21 in 1998 and 12/15 in 2000) showed normal median SEPs. The remainders had no median cortical responses. All 21 subjects in 1998 and 9 out of 15 in 2000 showed abnormalities of tibial SEPs mainly consisting of absence of cortical responses, prolonged cortical latencies, and central sensory delay to the lumbar spine. Most subjects showed normal absolute latencies both at peripheral and spinal levels. The SEP findings did not correlate with the severity, neither the duration of konzo, nor the experience or not of sensory symptoms at the onset of the disease.

CONCLUSION

Our findings are not specific of konzo. However, they suggest involvement of intracranial somatosensory pathways and point to similarities with other motor neuron diseases.

Для цитирования: Tshala-Katumbay D, Edebol Eeg-Olofsson K, Kazadi-Kayembe T, Fällmar Peo, Tylleskär Thorkild, Kayembe-Kalula T. Abnormalities of somatosensory evoked potentials in konzo--an upper motor neuron disorder.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2002. DOI: 10.1016/s1388-2457(01)00705-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.