Cardioverter-defibrillator implantation in high-risk patients with hypertrophic cardiomyopathy.

Almquist Adrian K, Montgomery Julia V, Haas Tammy S, Maron Barry J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Implantable cardioverter-defibrillators (ICDs) are used with increasing frequency in hypertrophic cardiomyopathy (HCM) patients of all ages for primary and secondary sudden death prevention. Concerns may arise regarding the safety of device implantation because of unique clinical and phenotypic expressions of HCM.

OBJECTIVES

The purpose of this study was to assess the efficacy and safety of ICD placement in high-risk patients with HCM.

METHODS

We analyzed the experience with ICDs and transvenous lead systems in 75 consecutive HCM patients at the Minneapolis Heart Institute from 1993 to 2004.

RESULTS

The age of the study group patients was 12 to 79 years (mean 36 +/- 16). Patients received ICDs for secondary (n = 4, after cardiac arrest) or primary prevention (n = 71, with > or = 1 risk factor). Thirty-one patients demonstrated disease features that potentially impacted methodology and safety of the implant procedure, most commonly massive left ventricular (LV) hypertrophy and outflow obstruction > or = 50 mmHg. There were no procedure-related deaths; defibrillator implants were successful and uneventful in 71 of 75 patients (95%). In 3 of the 75 patients (4%), defibrillation was unsuccessful because of high thresholds, associated with extreme hypertrophy (wall thickness > 45 mm) and/or ongoing amiodarone therapy. In two of these patients, thoracotomy with epicardial lead placement achieved successful defibrillation; ICD therapy was abandoned in the other patient.

CONCLUSION

ICD placement in children and adults with HCM is generally safe and effective. However, in some patients with massive LV hypertrophy and/or prior administration of amiodarone, transvenous defibrillation proved difficult, and epicardial lead placement was required. High-energy ICD devices and defibrillation threshold testing are recommended for most high-risk HCM patients.

Для цитирования: Almquist Adrian K, Montgomery Julia V, Haas Tammy S, Maron Barry J. Cardioverter-defibrillator implantation in high-risk patients with hypertrophic cardiomyopathy.. Heart rhythm. 2005. DOI: 10.1016/j.hrthm.2005.05.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.