MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2017.06.016

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2017

MLC tracking for lung SABR reduces planning target volumes and dose to organs at risk.

Caillet Vincent, Keall Paul J, Colvill Emma, Hardcastle Nicholas, O'Brien Ricky, Szymura Kathryn, Booth Jeremy T

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Assess the dosimetric impact of multi-leaf collimator (MLC) tracking and mid-ventilation (midV) planning compared with the internal target volume (ITV)-based planning approach for lung Stereotactic Ablative Body Radiotherapy (SABR).

METHOD: Ten lung SABR patients originally treated with an ITV-based plan were re-planned according to MLC tracking and midV planning schemes. All plans were delivered on a linac to a motion phantom in a simulated treatment with real lung motions. Delivered dose was reconstructed in patient planning scans. ITV-based, tracking and midV regimes were compared at the planning and delivered stages based on PTV volume and dose metrics for the GTV and OAR.

RESULTS

MLC tracking and midV schemes yielded favourable outcomes compared with ITV-based plans. Average reduction in PTV volume was (MLC tracking/MidV) 33.9%/22%. GTV dose coverage performed better with MLC tracking than the other regimes. Reduction in dose to OAR were for the lung (mean lung dose, 0.8Gy/0.2Gy), oesophagus (D3cc, 1.9Gy/1.4Gy), great vessels (D10cc, 3.2Gy/1.3Gy), trachea (D4cc, 1.1Gy/0.9Gy), heart (D1cc, 2.0Gy/0.5Gy) and spinal cord (D0.03cc, 0.5Gy/-0.1Gy).

CONCLUSION

MLC tracking showed reduction in PTV volume, superior GTV dose coverage and organ dose sparing than MidV and ITV-based strategies.

Для цитирования: Caillet Vincent, Keall Paul J, Colvill Emma, Hardcastle Nicholas, O'Brien Ricky, Szymura Kathryn, Booth Jeremy T. MLC tracking for lung SABR reduces planning target volumes and dose to organs at risk.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2017. DOI: 10.1016/j.radonc.2017.06.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.