MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11325-022-02677-0

Медицинская библиотека · Sleep & breathing = Schlaf & Atmung · 2022

Polygraphic evaluation of the effects of different rapid maxillary expansion appliances on sleep quality: A randomized clinical trial.

Gokce Gokcenur, Basoglu Ozen K, Veli Ilknur

Рандомизированное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this clinical study was to assess the effects of different rapid maxillary expansion appliances on the severity of obstructive sleep apnea (OSA).

MATERIAL AND

METHODS

Patients having a narrow maxilla and identified with OSA were divided randomly into three groups: tooth tissue-borne, tooth-borne, and bone-borne expanders. Changes in sleep parameters at baseline and 3-month follow-up detected by polygraphy were the primary outcome. Treatment of the crossbite was the secondary outcome. Dunn-Bonferroni tests, Kruskal-Wallis, and Wilcoxon analysis were applied for intra- and inter-group differences at p < 0.05 significance level.

RESULTS

Among 46 patients randomized, apnea-hypopnea index (AHI) changed from baseline to follow-up in all groups (- 1.6, p = 0.280; 0.6, p = 0.691; - 0.45, p = 0.796, respectively), with no between-group difference (p = 0.631). Oxygen desaturation index (ODI) altered from baseline to follow-up in all groups (0.80, p = 0.977; 0.20, p = 0.932; and - 1.00, p = 0.379, respectively), with no between-group difference (p = 0.858). There was no significant difference in minimum oxygen saturation from baseline to follow-up in all groups (0.00, p = 0.401; - 2.00, p = 0.887; 0.50, p = 0.407, respectively). No significant changes were observed in supine AHI from baseline to follow-up in all groups (0.00, p = 0.581; - 1.00, p = 0.393; 0.00, p = 0.972, respectively). The upper intermolar width increased from baseline to follow-up in all groups (5.04, p = 0.000; 3.15, p = 0.001; 5.41, p = 0.00, respectively) with no between-group difference (p = 0.560). Maxillary width increased from baseline to follow-up in all groups (4.25, p = 0.001; 4.74, p = 0.00; 4.49, p = 0.001, respectively) with no inter-group difference (p = 0.963).

CONCLUSIONS

The amount of skeletal and dental expansion obtained in the maxilla was similar in all groups. Rapid maxillary expansion was not found to be effective in OSA treatment.

TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04604392.

Для цитирования: Gokce Gokcenur, Basoglu Ozen K, Veli Ilknur. Polygraphic evaluation of the effects of different rapid maxillary expansion appliances on sleep quality: A randomized clinical trial.. Sleep & breathing = Schlaf & Atmung. 2022. DOI: 10.1007/s11325-022-02677-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.