MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1526602815579898

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2015

Inexplicable late type Ia endoleak associated with the low-profile Ovation endograft in a patient with favorable neck anatomy: treatment with transcaval coil embolization.

Gandini Roberto, Del Giudice Costantino, Abrignani Sergio, Vasili Erald, Pampana Enrico, Simonetti Giovanni

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report an unusual late type Ia endoleak after endovascular aneurysm repair with a low-profile sealing ring endograft and its treatment with transcaval sac embolization.

CASE REPORT: An 82-year-old man was treated for a 47-mm abdominal aortic aneurysm associated with a 35-mm left common iliac artery aneurysm using an Ovation Abdominal Stent Graft System. Correct endograft placement was documented at 3-month follow-up. Seven months after the repair, the patient was admitted to the emergency department with acute left inguinal pain. Computed tomography showed aneurysm sac enlargement (57 mm) and a contained rupture of the left common iliac artery due to a late type Ia endoleak. The endoleak was embolized with coils and thrombin via a transcaval approach. Sac shrinkage without signs of endoleak was observed at 12-month follow-up.

CONCLUSION

In this case, late endograft failure with sealing ring collapse created an inflow channel into the aneurysm sac, with massive type Ia endoleak.

Для цитирования: Gandini Roberto, Del Giudice Costantino, Abrignani Sergio, Vasili Erald, Pampana Enrico, Simonetti Giovanni. Inexplicable late type Ia endoleak associated with the low-profile Ovation endograft in a patient with favorable neck anatomy: treatment with transcaval coil embolization.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2015. DOI: 10.1177/1526602815579898.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.