MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/jov.26.2.7

Медицинская библиотека · Journal of vision · 2026

Sub-cone visual acuity can be achieved with less than 1 arcmin retinal slip.

Lukyanova Veronika, Ameln Julius, Witten Jenny L, Gutnikov Aleksandr, Freiberg Maximilian, Sayim Bilge, Harmening Wolf

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

The retinal area inspecting a visual stimulus and, consequently, the number of photoreceptors engaged in a visual task increase with presentation time, as fixational eye movements continuously move the retina across the retinal image. Here, we varied stimulus duration in a Tumbling-E visual acuity task while recording videos of the photoreceptor mosaic in seven participants with adaptive optics micro-psychophysical techniques to determine how far the retinal image must move across the cone mosaic before this motion begins to improve visual acuity. Five stimulus presentation durations were tested (3, 80, 220, 370, and 600 ms), while participants exhibited natural eye movements. Retinal slip amplitudes (i.e., the total displacement stimuli underwent) increased linearly with stimulus duration at individual rates. Higher cone density was associated with drift over smaller retinal areas, making the number of traversed cones more similar across participants at longer durations. At the shortest presentation duration, retinal slip was virtually absent and acuity was limited by retinal resolution, averaging to 1.07 ± 0.08 times the cone row-to-row spacing (Nyquist limit of sampling). At an 80-ms duration, corresponding to approximately two cone diameters of retinal slip, acuity thresholds improved significantly, reaching 0.90 ± 0.10 of the Nyquist limit. Thresholds continued to improve with longer durations at a lower rate, reaching 0.75 ± 0.10 times the Nyquist limit at 600 ms. These results demonstrate that humans can extract visual information with sub-cone precision within less than 100 ms, with a retinal slip approaching single foveal cone spacing.

Для цитирования: Lukyanova Veronika, Ameln Julius, Witten Jenny L, Gutnikov Aleksandr, Freiberg Maximilian, Sayim Bilge, Harmening Wolf. Sub-cone visual acuity can be achieved with less than 1 arcmin retinal slip.. Journal of vision. 2026. DOI: 10.1167/jov.26.2.7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.