The Canadian journal of cardiology · 2014
Association between drug-eluting stent type and clinical outcomes in patients with chronic kidney disease undergoing percutaneous coronary intervention.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chan William, Ivanov Joan, Kotowycz Mark A, Sibbald Matthew, McGeoch Ross, Crooks Noel, Hatton Rachael, Ing Douglas, Daly Paul, Mackie Karen, Osten Mark D, Seidelin Peter H, Barolet Alan, Overgaard Christopher B, Džavík Vladimír
Аннотация
BACKGROUND: The comparative efficacy of first- vs second-generation drug-eluting stents (DESs) in patients with chronic kidney disease (CKD) undergoing percutaneous coronary intervention (PCI) is unknown.
METHODS: A retrospective analysis of consecutive patients undergoing PCI at a tertiary PCI center from 2007-2011 was performed, with linkage to administrative databases for long-term outcomes. CKD was defined as creatinine clearance (CrCl) < 60 mL/min. Propensity matching by multivariable scoring method and Kaplan-Meier analyses were performed.
RESULTS: Of 6481 patients with available CrCl values undergoing a first PCI during the study period, 1658 (25%) had CKD. First- and second-generation DESs were implanted in 320 (19.3%) and 128 (7.7%) patients with CKD, respectively. At 2 years, no significant differences were observed between first-generation (n = 126) and second-generation (n = 126) propensity-matched DES cohorts for the outcomes of death (19% vs 16%; P = 0.51), repeat revascularization (10% vs 10%; P = 1.00), and major adverse cardiovascular and cerebrovascular events (MACCE) (36% vs 37%; P = 0.90). The 2-year Kaplan-Meier survival was also similar (P = 0.77). In patients with CKD, second-generation DES type was not an independent predictor for death (P = 0.49) or MACCE (P = 1.00).
CONCLUSIONS: Although the use of first- and second-generation DESs was associated with similar 2-year safety and efficacy in patients with CKD, our results cannot rule out a beneficial effect of second- vs first-generation DESs owing to small sample size. Future studies with larger numbers of patients with CKD are needed to identify optimal stent types, which may improve long-term clinical outcomes.
METHODS: A retrospective analysis of consecutive patients undergoing PCI at a tertiary PCI center from 2007-2011 was performed, with linkage to administrative databases for long-term outcomes. CKD was defined as creatinine clearance (CrCl) < 60 mL/min. Propensity matching by multivariable scoring method and Kaplan-Meier analyses were performed.
RESULTS: Of 6481 patients with available CrCl values undergoing a first PCI during the study period, 1658 (25%) had CKD. First- and second-generation DESs were implanted in 320 (19.3%) and 128 (7.7%) patients with CKD, respectively. At 2 years, no significant differences were observed between first-generation (n = 126) and second-generation (n = 126) propensity-matched DES cohorts for the outcomes of death (19% vs 16%; P = 0.51), repeat revascularization (10% vs 10%; P = 1.00), and major adverse cardiovascular and cerebrovascular events (MACCE) (36% vs 37%; P = 0.90). The 2-year Kaplan-Meier survival was also similar (P = 0.77). In patients with CKD, second-generation DES type was not an independent predictor for death (P = 0.49) or MACCE (P = 1.00).
CONCLUSIONS: Although the use of first- and second-generation DESs was associated with similar 2-year safety and efficacy in patients with CKD, our results cannot rule out a beneficial effect of second- vs first-generation DESs owing to small sample size. Future studies with larger numbers of patients with CKD are needed to identify optimal stent types, which may improve long-term clinical outcomes.