BACKGROUND

Peripherally inserted central catheters (PICCs) are used to deliver continuous intravenous (IV) milrinone in stage D heart failure (HF) patients awaiting heart transplantation (HT).

METHODS

We retrospectively analyzed PICC adverse events (AEs) and associated cost in 129 status 1B patients from 2005 to 2012. End points were HT, left ventricular assist device (LVAD), and death. Regression analysis was used to identify AE risk factors.

RESULTS

Fifty-three PICC AEs occurred in 35 patients (27%), consisting of 48 infections, 4 thromboses, and 1 bleeding event. Median duration of PICC support was 63 (interquartile range [IQR] 34-131) days, and median time to first PICC infection was 44 (IQR 14-76) days. Among PICC infections, 9% required defibrillator removal and 30% were inactivated on the HT list for a mean of 23 ± 17 days. Rate of HT, LVAD, or death was similar between groups (P > .05). Regression analysis found that a double lumen PICC was associated with a shorter time to first PICC infection (hazard ratio 7.59, 95% CI 1.97-29.23; P = .003). Median cost per PICC infection was $10,704 (IQR $7,401-$26,083).

CONCLUSIONS

PICC infections were the most frequent AEs. PICCs with >1 lumen were associated with increased risk of infection. PICC AEs accounted for increased intensive care unit admissions, HT list inactivations, and overall cost.

Для цитирования: Haglund Nicholas A, Cox Zachary L, Lee Jeff T, Song Yanna, Keebler Mary E, DiSalvo Thomas G, Maltais Simon, Lenihan Daniel J, Wigger Mark A. Are peripherally inserted central catheters associated with increased risk of adverse events in status 1B patients awaiting transplantation on continuous intravenous milrinone?. Journal of cardiac failure. 2014. DOI: 10.1016/j.cardfail.2014.06.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.