MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-012-2414-9

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2012

Instability of treated vertebrae after balloon kyphoplasty causing paraparesis in osteoporotic vertebral compression fracture: a report of two cases.

Ohba Tetsuro, Ebata Shigeto, Clinton Devin, Koyama Kenske, Haro Hirotaka

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe two unique cases of osteoporotic vertebral compression fracture (OVCF) treated with balloon kyphoplasty (BKP) that were complicated by spinal instability and resultant lower extremity paraparesis.

METHODS

Kyphoplasty was performed in two patients with OVCF that had persistent back pain despite a course of conservative care. Immediately following BKP, both patients had a marked improvement in back pain. However, they developed progressive bilateral lower extremity weakness. Lateral spine flexion-extension radiographs demonstrated instability, and polymethyl methacrylate did not adhere to the endplate of the treated vertebrae.

RESULTS

Both the patients underwent a hybrid fixation without a decompression. Postoperatively, both of them demonstrated gradual improvement in their neurological exam.

CONCLUSIONS

To the best of our knowledge, this is the first report describing the development of spinal instability with resultant delayed paraplegia following BKP. This case report demonstrates another cause of neurological decline following BKP, in the absence of cement leakage.

Для цитирования: Ohba Tetsuro, Ebata Shigeto, Clinton Devin, Koyama Kenske, Haro Hirotaka. Instability of treated vertebrae after balloon kyphoplasty causing paraparesis in osteoporotic vertebral compression fracture: a report of two cases.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2012. DOI: 10.1007/s00586-012-2414-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.