MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11307-016-0954-9

Медицинская библиотека · Molecular imaging and biology · 2016

Novel Approach to Repeated Arterial Blood Sampling in Small Animal PET: Application in a Test-Retest Study with the Adenosine A1 Receptor Ligand [(11)C]MPDX.

Sijbesma Jürgen W A, Zhou Xiaoyun, Vállez García David, Houwertjes Martin C, Doorduin Janine, Kwizera Chantal, Maas Bram, Meerlo Peter, Dierckx Rudi A, Slart Riemer H J A, Elsinga Philip H, van Waarde Aren

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Small animal positron emission tomography (PET) can be used to detect small changes in neuroreceptor availability. This often requires rapid arterial blood sampling. However, current catheterization procedures do not allow repeated blood sampling. We have developed a procedure which allows arterial sampling on repeated occasions in the same animal.

PROCEDURES: Eleven male Wistar rats were two times catheterized via a superficial branch of a femoral artery and scanned with [(11)C]MPDX and blood sampling. PET images were co-registered to a magnetic resonance imaging (MRI) template. Regional tracer distribution volumes (V T) in the brain were calculated by the Logan analysis. The procedure was repeated after 1 week.

RESULTS

Surgery was successful in 90 % of the cases, and discomfort was minor. The V T data showed small differences between test and retest, low between subject variability, and a strong agreement between and within subjects.

CONCLUSION

Repeated quantitative imaging with a high reproducibility is possible with this approach.

Для цитирования: Sijbesma Jürgen W A, Zhou Xiaoyun, Vállez García David, Houwertjes Martin C, Doorduin Janine, Kwizera Chantal, Maas Bram, Meerlo Peter, Dierckx Rudi A, Slart Riemer H J A, Elsinga Philip H, van Waarde Aren. Novel Approach to Repeated Arterial Blood Sampling in Small Animal PET: Application in a Test-Retest Study with the Adenosine A1 Receptor Ligand [(11)C]MPDX.. Molecular imaging and biology. 2016. DOI: 10.1007/s11307-016-0954-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.