MedElevator Войти в исследования
← Поиск публикаций

DOI 10.33963/kp.a2021.0167

Медицинская библиотека · Kardiologia polska · 2021

Can we improve the accuracy of electrocardiographic algorithms for accessory pathway location in children?

Ferrari Paola, Malanchini Giovanni, Racheli Marco, Ferrari Gabriele, Leidi Cristina, Cerea Paolo, Senni Michele, Della Bella Paolo, Malacrida Maurizio, Gulletta Simone, De Filippo Paolo

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Predicting an accessory pathway location is extremely important in pediatric patients.

AIMS: We designed a study to compare previously published algorithms by Arruda, Boersma, and Chiang.

METHODS

This multicenter study included patients who had undergone successful ablation of one accessory pathway. Analysis of resting 12-lead electrocardiograms was carried out. An aggregated prediction score was constructed on the basis of algorithm agreement, and a structured workflow approach was proposed.

RESULTS

The total population was 120 patients (mean age, 12.7 [± 3.6] years). The algorithm by Boersma had the highest accuracy (71.7%). The inter-rater agreement among the 3 reference algorithms, according to left-sided accessory pathway (AP) identification, was good between Boersma and Chiang (κ = 0.611; 95% confidence interval [CI], 0.468-0.753) but moderate between Arruda and Chiang and between Arruda and Boersma (κ = 0.566; 95% CI, 0.419-0.713 and κ = 0.582; 95% CI, 0.438-0.727, respectively). Regarding locations at risk of atrioventricular (AV) block, agreement was fair between Arruda and Chiang and between Boersma and Chiang (κ = 0.358; 95% CI, 0.195-0.520 and κ = 0.307; 95% CI, 0.192-0.422, respectively) but moderate between Arruda and Boersma (κ = 0.45; 95% CI, 0.304-0.597). On applying a first-step diagnostic evaluation, when concordance was achieved, we were able to correctly identify left-sided or non-left-sided ablation sites in 96.4% (n = 80) of cases. When concordance was achieved, correct prediction of risk/no risk of AV block was achieved in 92.2% (n = 59) of cases.

CONCLUSIONS

An aggregated prediction score based on 3 reference algorithms proved able to predict an accessory pathway location very precisely and could be used to plan safely invasive procedures.

Для цитирования: Ferrari Paola, Malanchini Giovanni, Racheli Marco, Ferrari Gabriele, Leidi Cristina, Cerea Paolo, Senni Michele, Della Bella Paolo, Malacrida Maurizio, Gulletta Simone, De Filippo Paolo. Can we improve the accuracy of electrocardiographic algorithms for accessory pathway location in children?. Kardiologia polska. 2021. DOI: 10.33963/kp.a2021.0167.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.