DOI 10.1016/j.avsg.2011.09.006
Challenging treatment of multiple late complications after endovascular aneurysm repair.
Аннотация
BACKGROUND
To report a case of multiple additional procedures after successful endovascular treatment of abdominal aortic aneurysm.
METHODS
An endovascular abdominal aortic aneurysm repair with a bifurcated aortic Vanguard endograft successfully performed in 1999 resulted in multiple complications, including endoleaks and a row separation, treated endovascularly. Subsequently, tuberculosis sepsis and prosthesis infection resulted in long-term antibiotic treatment. Additional graft leaks, aneurysm sack growth, and sack ruptures were also treated endovascularly because the patient consistently denied open repair. Endovascular procedures, however, did not solve the problem, turning to be increasingly challenging. The patient finally approved open graft removal and aortobifemoral reconstruction that were successfully performed 11 years after the initial endograft implantation.
RESULTS
The patient has recovered from surgery well and is asymptomatic. No evidence of bacterial colonization was found according to the specimen taken during the laparotomy.
CONCLUSION
Vanguard and other first-generation aortic endografts are associated with high incidence of complications and reinterventions. Open surgery is a method of choice in similar cases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.