Test-retest and inter-rater reliability and construct validity of the 2-minute step test in individuals with Parkinson's disease.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Santos Marina Genari Murad Carolino Dos, Benazzi Fabiana Acorse Francischetti, Uhdre André Luis, Dibai-Filho Almir Vieira
Аннотация
OBJECTIVE: To evaluate the test-retest and inter-rater reliability and construct validity of the 2-min step test (2MST) in individuals with Parkinson's disease (PD).
METHODS: Two previously trained examiners applied the 2MST in two moments. Clinical measurements of PD were obtained using the following instruments: Berg Balance Scale (BBS), Unified Parkinson's Disease Rating Scale (UPDRS), modified Hoehn and Yahr Scale (H&Y), gait speed and cadence, 5-time Sit-to-Stand Test (5TSST) and Timed Up and Go (TUG). For reliability, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC) were calculated. For construct validity, Pearson's and Spearman's correlation coefficient were used. The agreement between the measurement in person and via recorded video was assessed by means of Bland-Altman plots.
RESULTS: The 2MST showed adequate test-retest reliability (ICC = 0.80, SEM = 10.59, MDC = 29.35) and excellent inter-rater reliability (ICC = 0.93, SEM = 4.49, MDC = 12.46). There was acceptable agreement between assessments made with in person and via video. A correlation magnitude above 0.50 was found between 2MST and gait speed, and a correlation magnitude between 0.30 and 0.50 with BBS, gait cadence, UPDRS and TUG.
CONCLUSION: The 2MST presents adequate test-retest and inter-rater reliability and a valid construct to evaluate the aerobic endurance of individuals with PD.
METHODS: Two previously trained examiners applied the 2MST in two moments. Clinical measurements of PD were obtained using the following instruments: Berg Balance Scale (BBS), Unified Parkinson's Disease Rating Scale (UPDRS), modified Hoehn and Yahr Scale (H&Y), gait speed and cadence, 5-time Sit-to-Stand Test (5TSST) and Timed Up and Go (TUG). For reliability, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC) were calculated. For construct validity, Pearson's and Spearman's correlation coefficient were used. The agreement between the measurement in person and via recorded video was assessed by means of Bland-Altman plots.
RESULTS: The 2MST showed adequate test-retest reliability (ICC = 0.80, SEM = 10.59, MDC = 29.35) and excellent inter-rater reliability (ICC = 0.93, SEM = 4.49, MDC = 12.46). There was acceptable agreement between assessments made with in person and via video. A correlation magnitude above 0.50 was found between 2MST and gait speed, and a correlation magnitude between 0.30 and 0.50 with BBS, gait cadence, UPDRS and TUG.
CONCLUSION: The 2MST presents adequate test-retest and inter-rater reliability and a valid construct to evaluate the aerobic endurance of individuals with PD.