DOI 10.1016/j.jdent.2025.105600
Ion-releasing resin composites prevent demineralization around restorations in an in-vitro biofilm model.
Аннотация
OBJECTIVE
This study aimed to evaluate the effectiveness of two ion-releasing, resin-based composites (RBCs), ACTIVA BioACTIVE-Restorative (BIO1) and ACTIVA Presto (BIO2), in preventing demineralization around restorations.
METHODS
Class I and II cavities were prepared on bovine (n = 4) and human teeth (n = 8) and restored with BIO1, BIO2, a conventional composite (RBC, Filtek Supreme XTE), and a resin-modified glass ionomer cement (RMGIC, Ionolux). Following restorations (class I, n= 16/material; class II, n= 8/material), the specimens were exposed to Streptococcus mutans biofilm in a continuous-flow bioreactor over two weeks. Micro-computed tomography (micro-CT) assessed demineralization depths at restoration margins, and supernatant pH changes were measured after a 24-h acidic challenge. Statistical analyses included one and two-way ANOVA and Tukey's test (p < 0.05).
RESULTS
On enamel surfaces, RMGIC showed no demineralization, followed by BIO1 (≈50 μm), BIO2 (≈125 μm), and RBC (≈150 μm). No difference between human or bovine enamel was observed. In dentin, RMGIC showed the least demineralization (≈190 μm), followed by BIO1 (≈230 μm), BIO2 (≈280 μm), and RBC (≈400 μm). pH buffering was highest in RMGIC (+ 0.24 pH), while BIO1, BIO2, and RBC showed similar buffering capacities (∼ +0.1 pH). Gaps were found at several interfaces for BIO1 and RMGIC.
CONCLUSIONS
Ion-releasing RBCs varied in effectiveness for reducing demineralization of surrounding tissues, with limited pH buffering capacity. RMGIC exhibited better performance. Gaps between cavity walls and BIO1/RMGIC raised concerns about long-term adhesion.
CLINICAL SIGNIFICANCE: ACTIVA BioACTIVE Restorative (BIO1) and ACTIVA Presto (BIO2) resin-based composites promoted slight inhibition of demineralization in an in-vitro biofilm model, suggesting that further modifications in their chemical composition are necessary.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.