Rahmany Ines, Nemmala Mohamed El Arbi, Khlifa Nawres, Megdiche Houda

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Intracranial aneurysms (IA) are abnormal dilatation of the arteries at the circle of Willis whose rupture can lead to catastrophic complications such as hemorrhagic stroke. The purpose of this work is to detect IA in 2D-DSA images. The proposed detection framework uses local binary patterns for the determination of initial aneurysm candidates and generic Fourier descriptor (GFD) for false positive removal.

METHODS

Here, the designed framework takes DSA images including IA as input and produces images where the IA is clearly identified and localized. The multi-step approach is defined as the following: The first phase presents the determination of initial aneurysm candidates using the uniform local binary patterns (LBPs). The LBPs are calculated from these images in order to identify texture contents of both aneurysm and no-aneurysm classes. The second phase presents the false positives removal using a shape descriptor based on contours: the GFD.

RESULTS

We demonstrated that the proposed detection method successfully recognized morphological features of intracranial aneurysm. The results demonstrated excellent agreement between manual and automated detections. With the computerized IA detection framework, all aneurysms were correctly detected with zero false negative and low FP rates.

CONCLUSION

This study shows the potential of LBP and GFD as a feature descriptors and paves the way for a whole image analysis tool to predict intracranial aneurysm risk of rupture.

Для цитирования: Rahmany Ines, Nemmala Mohamed El Arbi, Khlifa Nawres, Megdiche Houda. Automatic detection of intracranial aneurysm using LBP and Fourier descriptor in angiographic images.. International journal of computer assisted radiology and surgery. 2019. DOI: 10.1007/s11548-019-01996-0.