MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a8914

Медицинская библиотека · AJNR. American journal of neuroradiology · 2025

CONSeg: Voxelwise Uncertainty Quantification for Glioma Segmentation Using Conformal Prediction.

Elyassirad Danial, Gheiji Benyamin, Vatanparast Mahsa, Ahmadzadeh Amir Mahmoud, Faghani Shahriar

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Accurate glioma segmentation has the potential to enhance clinical decision-making and treatment planning. Uncertainty quantification methods, including conformal prediction (CP), can enhance segmentation models reliability. CP quantifies uncertainty with statistical confidence guarantees. This study aimed to use CP in glioma segmentation.

MATERIALS AND

METHODS

We used the publicly available University of California San Francisco (UCSF) and University of Pennsylvania (UPenn) glioma data sets, with the UCSF data set (495 cases) split into training (70%), validation (10%), calibration (10%), and test (10%) sets, and the UPenn data set (147 cases) divided into external calibration (30%) and external test (70%) sets. A UNet model was trained, and its optimal threshold was set to 0.5 using prediction normalization. To apply CP, we selected the conformal threshold on the basis of the internal/external calibration nonconformity score, and CP was subsequently applied to the internal/external test sets with coverage. The proportion of true labels within prediction sets was reported for all. We defined the uncertainty ratio (UR) and assessed its correlation with the DSC and 95th percentile Hausdorff distance (HD95). Additionally, we categorized cases into certain and uncertain groups on the basis of UR and compared their DSC and HD95. We also evaluated the correlation between UR and the evaluation metrics (DSC and HD95) of the Brain Tumor Segmentation (BraTS) fusion model segmentation and compared evaluation metrics in the certain and uncertain subgroups.

RESULTS

The base model achieved a DSC of 0.86 and 0.83 and an HD95 of 7.35 and 11.71 on the internal and external test sets, respectively. The CP coverage was 0.9982 for the internal test set and 0.9977 for the external test set. Statistical analysis showed significant correlations between UR and the evaluation metrics for test sets (P value < .001). Additionally, certain cases had significantly better evaluation metrics (higher DSC and lower HD95) than uncertain cases in the test sets and the BraTS fusion model segmentation (P value < .001).

CONCLUSIONS

CP effectively quantifies uncertainty in glioma segmentation. Using conformal segmentation (CONSeg) improves the reliability of segmentation models and enhances human-computer interactions. Additionally, CONSeg can identify uncertain cases and suggest them for manual segmentation.

Для цитирования: Elyassirad Danial, Gheiji Benyamin, Vatanparast Mahsa, Ahmadzadeh Amir Mahmoud, Faghani Shahriar. CONSeg: Voxelwise Uncertainty Quantification for Glioma Segmentation Using Conformal Prediction.. AJNR. American journal of neuroradiology. 2025. DOI: 10.3174/ajnr.a8914.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.