MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijph.ijph_464_18

Медицинская библиотека · Indian journal of public health · 2020

Intravenous Iron sucrose and change in hemoglobin, ferritin, and oxidative stress markers among moderately anemic pregnant women attending a secondary care level Hospital in Northern India.

Jacob Olivia Marie, Kant Shashi, Haldar Partha, Kaur Ravneet, Dadhwal Vatsla, Prakash Shyam

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Intravenous iron is associated with oxidative stress, and very few studies have assessed change in oxidative stress markers post infusion.

OBJECTIVES

The study aimed to measure the change in levels of hemoglobin (Hb), serum ferritin, and select oxidative stress markers (malondialdehyde [MDA], superoxide dismutase [SOD], and ferric reducing ability of plasma [FRAP]) 4 weeks following the administration of intravenous iron sucrose (IVIS) among moderately anemic pregnant women who were attending a secondary-level health-care facility, Haryana, North India.

METHODS

An observational study was conducted (May 2016 to Jan 2018) among pregnant women receiving intravenous iron sucrose i.e., IVIS (300 mg per dose) diluted in 300 mL of normal saline over 20-45 min and were followed up for a period of 4 weeks after the last dose of IVIS (end line). The study outcomes were measured in the levels of Hb, serum ferritin, MDA, SOD, and FRAP from the baseline to the end line.

RESULTS

The mean (95% confidence interval) change in the Hb and serum ferritin level 4 weeks after the last dose of IVIS was an increase of 2.5 (2.1-3.0) g/dL (P < 0.001) and 63.0 (44.7-81.3) ng/mL (P < 0.001), respectively. There were no significant changes (baseline to end line) in mean (standard deviation [SD]) MDA level and mean (SD) FRAP level. The mean (SD) SOD level declined significantly (2.2 [0.4] U/mL to 1.6 [0.5] U/mL [P < 0.001]). No life-threatening adverse events were encountered during the study.

CONCLUSION

IVIS was well tolerated and effective in treating moderate anemia in pregnancy. Body iron store was replenished following IVIS administration. There was no increase in oxidative stress following IVIS therapy.

Для цитирования: Jacob Olivia Marie, Kant Shashi, Haldar Partha, Kaur Ravneet, Dadhwal Vatsla, Prakash Shyam. Intravenous Iron sucrose and change in hemoglobin, ferritin, and oxidative stress markers among moderately anemic pregnant women attending a secondary care level Hospital in Northern India.. Indian journal of public health. 2020. DOI: 10.4103/ijph.ijph_464_18.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.