Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2011

Endovascular treatment of patients with types A and B thoracic aortic dissection using Relay thoracic stent-grafts: results from the RESTORE Patient Registry.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zipfel Burkhart, Czerny Martin, Funovics Martin, Coppi Gioacchino, Ferro Carlo, Rousseau Hervé, Berti Sergio, Tealdi Domenico G, Riambau Vincent, Mangialardi Nicola, Sassi Carlo, RESTORE Investigators

Аннотация

PURPOSE: To evaluate the safety and performance of Relay stent-grafts in patients with acute or chronic aortic dissections.

METHODS: Patients with types A or B aortic dissections suitable for treatment with Relay stent-grafts and followed for 2 years after thoracic endovascular aortic repair (TEVAR) were identified from a company-sponsored registry database established in January 2006. Ninety-one consecutive patients (69 men; mean age 65 years) underwent TEVAR with Relay stent-grafts for dissection. Most patients (76, 84%) had type B dissections; 61 of all patients were classified as chronic and 30 as acute.

RESULTS: The technical success rate was 95% (97% in acute, 95% in chronic, and 93% in type B dissections). The type I endoleak rate was 7% (7% in acute and 8% in chronic dissections); all occurred in patients with type B dissections. Paraplegia, paraparesis, and stroke occurred in 4, 1, and 2 patients, respectively; 2 cases of paraplegia occurred in patients with acute type B dissections. Thirty-day mortality was 8% (13% in acute and 5% in chronic dissections); all deaths occurred in patients with type B dissections. The 2-year survival rate was 82% in the overall population and 84% in patients with type B dissections.

CONCLUSION: The combination of Relay's features, such as stent conformability, radial force, atraumatic design, and controlled deployment and fixation, may contribute to the safety of the Relay stent-grafts for the treatment of thoracic aortic dissections, including acute and chronic type B dissections.