MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1583/10-3233mr.1

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2011

Endovascular treatment of patients with types A and B thoracic aortic dissection using Relay thoracic stent-grafts: results from the RESTORE Patient Registry.

Zipfel Burkhart, Czerny Martin, Funovics Martin, Coppi Gioacchino, Ferro Carlo, Rousseau Hervé, Berti Sergio, Tealdi Domenico G, Riambau Vincent, Mangialardi Nicola, Sassi Carlo, RESTORE Investigators

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety and performance of Relay stent-grafts in patients with acute or chronic aortic dissections.

METHODS

Patients with types A or B aortic dissections suitable for treatment with Relay stent-grafts and followed for 2 years after thoracic endovascular aortic repair (TEVAR) were identified from a company-sponsored registry database established in January 2006. Ninety-one consecutive patients (69 men; mean age 65 years) underwent TEVAR with Relay stent-grafts for dissection. Most patients (76, 84%) had type B dissections; 61 of all patients were classified as chronic and 30 as acute.

RESULTS

The technical success rate was 95% (97% in acute, 95% in chronic, and 93% in type B dissections). The type I endoleak rate was 7% (7% in acute and 8% in chronic dissections); all occurred in patients with type B dissections. Paraplegia, paraparesis, and stroke occurred in 4, 1, and 2 patients, respectively; 2 cases of paraplegia occurred in patients with acute type B dissections. Thirty-day mortality was 8% (13% in acute and 5% in chronic dissections); all deaths occurred in patients with type B dissections. The 2-year survival rate was 82% in the overall population and 84% in patients with type B dissections.

CONCLUSION

The combination of Relay's features, such as stent conformability, radial force, atraumatic design, and controlled deployment and fixation, may contribute to the safety of the Relay stent-grafts for the treatment of thoracic aortic dissections, including acute and chronic type B dissections.

Для цитирования: Zipfel Burkhart, Czerny Martin, Funovics Martin, Coppi Gioacchino, Ferro Carlo, Rousseau Hervé, Berti Sergio, Tealdi Domenico G, Riambau Vincent, Mangialardi Nicola, Sassi Carlo, RESTORE Investigators. Endovascular treatment of patients with types A and B thoracic aortic dissection using Relay thoracic stent-grafts: results from the RESTORE Patient Registry.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2011. DOI: 10.1583/10-3233mr.1.