MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0322102

Медицинская библиотека · PloS one · 2025

Diagnostic performance of microvascular flow imaging for noninvasive assessment of liver fibrosis in chronic liver disease.

Yoo Hae Won, Yang Chan Jin, Yoo Jeong-Ju, Chang Young, Lee Sae Hwan, Jeong Soung Won, Jang Jae Young, Cheon Gab Jin, Kim Young Seok, Kim Hong Soo, Kim Sang Gyune

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Chronic liver disease (CLD) represents a significant global health challenge necessitating the evaluation of liver fibrosis. This study aimed to evaluate the diagnostic performance of microvascular flow (MV-flow) imaging in evaluating liver fibrosis and compare it with other non-invasive tools.

METHODS

Between July 2020 and June 2022, we prospectively enrolled patients scheduled for liver biopsy, concurrently measuring MV-flow imaging, transient elastography (TE), and two-dimensional shear wave elastography (2D-SWE) as part of the assessment process. We evaluated the diagnostic performance of MV-flow imaging, 2D-SWE, and TE based on histologic staging of liver fibrosis using the area under the receiver operating characteristic curve (AUROC), and calculated the optimal cut-off value.

RESULTS

A total of 89 participants were included. Non-alcoholic fatty liver disease was the most common etiology of CLD (32.6%). The liver fibrosis stage distribution was as follows: stage 0 (11.2%), stage 1 (31.5%), stage 2 (25.8%), stage 3 (13.5%), and stage 4 (18.0%). The MV-flow scoring system's cut-off values and AUROCs for predicting stage 2, stage 3, and cirrhosis were 2.1 (0.836), 2.5 (0.955), and 2.9 (0.942), respectively. The MV-flow scoring system's performance in predicting advanced fibrosis (stage 3) was comparable to TE (p = 0.170) and 2D-SWE (p = 0.456). MV-flow imaging misclassified 9.0% of patients in predicting advanced fibrosis. A sequential combination of 2D-SWE and MV-flow imaging, following the specified cut-off, minimized the risk of missing advanced fibrosis to 1.2%.

CONCLUSION

MV-flow imaging is an effective tool for predicting liver fibrosis stage. Integrating MV-flow imaging with 2D-SWE can enhance the assessment of liver fibrosis in patients with CLD.

Для цитирования: Yoo Hae Won, Yang Chan Jin, Yoo Jeong-Ju, Chang Young, Lee Sae Hwan, Jeong Soung Won, Jang Jae Young, Cheon Gab Jin, Kim Young Seok, Kim Hong Soo, Kim Sang Gyune. Diagnostic performance of microvascular flow imaging for noninvasive assessment of liver fibrosis in chronic liver disease.. PloS one. 2025. DOI: 10.1371/journal.pone.0322102.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.