DOI 10.1212/wnl.0000000000009289
Prognostic value of diffusion-weighted MRI for post-cardiac arrest coma.
Аннотация
OBJECTIVE
To validate quantitative diffusion-weighted imaging (DWI) MRI thresholds that correlate with poor outcome in comatose cardiac arrest survivors, we conducted a clinician-blinded study and prospectively obtained MRIs from comatose patients after cardiac arrest.
METHODS
Consecutive comatose post-cardiac arrest adult patients were prospectively enrolled. MRIs obtained within 7 days after arrest were evaluated. The clinical team was blinded to the DWI MRI results and followed a prescribed prognostication algorithm. Apparent diffusion coefficient (ADC) values and thresholds differentiating good and poor outcome were analyzed. Poor outcome was defined as a Glasgow Outcome Scale score of ≤2 at 6 months after arrest.
RESULTS
Ninety-seven patients were included, and 75 patients (77%) had MRIs. In 51 patients with MRI completed by postarrest day 7, the prespecified threshold of >10% of brain tissue with an ADC <650 ×10-6 mm2/s was highly predictive for poor outcome with a sensitivity of 0.63 (95% confidence interval [CI] 0.42-0.80), a specificity of 0.96 (95% CI 0.77-0.998), and a positive predictive value (PPV) of 0.94 (95% CI 0.71-0.997). The mean whole-brain ADC was higher among patients with good outcomes. Receiver operating characteristic curve analysis showed that ADC <650 ×10-6 mm2/s had an area under the curve of 0.79 (95% CI 0.65-0.93, p < 0.001). Quantitative DWI MRI data improved prognostication of both good and poor outcomes.
CONCLUSIONS
This prospective, clinician-blinded study validates previous research showing that an ADC <650 ×10-6 mm2/s in >10% of brain tissue in an MRI obtained by postarrest day 7 is highly specific for poor outcome in comatose patients after cardiac arrest.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.