MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jisppd.jisppd_173_21

Медицинская библиотека · Journal of the Indian Society of Pedodontics and Preventive Dentistry · 2022

Cephalometric evaluation of the cervical spine posture following fixed functional therapy with Forsus™ appliance.

Malik Nidhi, Fernandes Bennete Aloysius, Ramamurthy Priyadarshini Hesarghatta, Anjum Shagufta, Prakash Amit, Sinha Abhik

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To investigate whether fixed functional therapy for mandibular advancement with the Forsus™ appliance would produce any changes in the cervical spine posture.

MATERIALS AND

METHODS

This prospective clinical exploratory study was conducted on 12 patients (six females and six males) with a mean age of 15 ± 1.3 years, having mandibular retrusion, Class II malocclusion, who were treated with the Forsus™ appliance. Lateral cephalogram was taken twice, once at the baseline (T1) before the commencement of the treatment and once following termination of fixed functional treatment (T2). Eleven measurements representing the vertical and the sagittal craniofacial proportions, and the head posture, were taken into account. Data were analyzed using SPSS version 22. The variations between before and after treatment measurements were collated using paired t-test. P < 0.05 was considered statistically significant.

RESULTS

No significant differences were noticed in the angle linking the horizontal lines of the head and the superior crest of the spinal column before and after the treatment, with P = 0.73. The cervical curvature angle also failed to show any significant difference with P = 0.14.

CONCLUSION

Fixed functional therapy with the Forsus™ device resulted in dentoalveolar and soft tissue alterations alone but did not alter the cervical spine posture.

Для цитирования: Malik Nidhi, Fernandes Bennete Aloysius, Ramamurthy Priyadarshini Hesarghatta, Anjum Shagufta, Prakash Amit, Sinha Abhik. Cephalometric evaluation of the cervical spine posture following fixed functional therapy with Forsus™ appliance.. Journal of the Indian Society of Pedodontics and Preventive Dentistry. 2022. DOI: 10.4103/jisppd.jisppd_173_21.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.