Development and validation of the low-cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy.

Kopačin Vjekoslav, Brkić Hrvoje, Ivković Ana, Kasabašić Mladen, Knežević Željka, Majer Marija, Nodilo Marijana, Turk Tajana, Faj Dario

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman.

PURPOSE: In this study, the development of a low-cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom.

METHODS

Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment.

RESULTS

Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%.

CONCLUSIONS

Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.

Для цитирования: Kopačin Vjekoslav, Brkić Hrvoje, Ivković Ana, Kasabašić Mladen, Knežević Željka, Majer Marija, Nodilo Marijana, Turk Tajana, Faj Dario. Development and validation of the low-cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy.. Journal of applied clinical medical physics. 2023. DOI: 10.1002/acm2.14240.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.