MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajodo.2011.05.020

Медицинская библиотека · American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2011

Cortical bone thickness and bone depth of the posterior palatal alveolar process for mini-implant insertion in adults.

Baumgaertel Sebastian

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Cortical bone thickness and bone depth are important factors when placing an orthodontic mini-implant. The objective of this study was to investigate both variables for the palatal alveolar process.

METHODS

Thirty dry human skulls were imaged by using cone-beam computed tomography technology. Two-dimensional slices bisecting the posterior interdental sites were generated, and cortical bone thickness and bone depth were measured at 4, 8, and 12 mm from the alveolar crest. Two-way repeated measures analysis of variance (ANOVA) was used to analyze the measurements.

RESULTS

Interdental site and measurement level had a significant impact on both cortical bone thickness and bone depth. Cortical bone thickness was typically greatest at the 8-mm measurement level and more anterior interdental sites. Bone depth decreased with higher measurement levels and was smallest at the most posterior-superior measurement points.

CONCLUSIONS

Cortical bone thickness and bone depth of the palatal alveolar process are, on average, favorable for the insertion of orthodontic mini-implants; however, some sites should routinely be avoided to prevent damage to the maxillary sinus unless 3-dimensional imaging is available.

Для цитирования: Baumgaertel Sebastian. Cortical bone thickness and bone depth of the posterior palatal alveolar process for mini-implant insertion in adults.. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. 2011. DOI: 10.1016/j.ajodo.2011.05.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.