MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1600-0501.2010.02021.x

Медицинская библиотека · Clinical oral implants research · 2010

Vertical palatal bone dimensions on lateral cephalometry and cone-beam computed tomography: implications for palatal implant placement.

Jung Britta A, Wehrbein Heinrich, Heuser Lothar, Kunkel Martin

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the necessity of three-dimensional imaging (computed tomography [CT]/cone-beam computed tomography [CBCT]) for paramedian insertion of palatal implants.

MATERIAL AND

METHODS

Lateral radiographs and CBCT scans were performed from 18 human skulls. For lateral cephalometry, the nasal floor (right/left) and the oral hard palate of all skulls were lined with a tin foil for contrast enhancement. The quantity of vertical bone as measured on lateral radiographs was compared with CBCT measurements obtained in median and parasagittal planes and at minimum bone height. Spearman's rank correlation coefficients were determined for bivariate correlation analysis.

RESULTS

The median palatal bone height on CBCT (mean 8.98 mm; standard deviation [SD] 3.4) was markedly higher than the vertical height seen on lateral radiographs (mean 6.6 mm; SD 3.2). Comparing lateral cephalometry with CBCT, the strongest association was observed at the minimum palatal bone height (r=0.926; P<0.001; Spearman's rank correlation coefficient).

CONCLUSIONS

Lateral radiographs allow accurate and adequate assessment of vertical bone before paramedian insertion of palatal implants. The vertical bone dimension as displayed on lateral cephalometry reflects the minimum bone height rather than maximum bone in the median plane. Therefore, a preoperative CT or CBCT is only indicated when the lateral cephalometry reveals a marginal quantity of bone.

Для цитирования: Jung Britta A, Wehrbein Heinrich, Heuser Lothar, Kunkel Martin. Vertical palatal bone dimensions on lateral cephalometry and cone-beam computed tomography: implications for palatal implant placement.. Clinical oral implants research. 2010. DOI: 10.1111/j.1600-0501.2010.02021.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.