Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2023
Improvement of diagnostic performance of hyperacute ischemic stroke in head CT using an image-based noise reduction technique with non-black-boxed process.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hirairi Tetsuya, Ichikawa Katsuhiro, Urikura Atsushi, Kawashima Hiroki, Tabata Takasumi, Matsunami Tamaki
Аннотация
PURPOSE: This study aims to investigate whether an image-based noise reduction (INR) technique with a conventional rule-based algorithm involving no black-boxed processes can outperform an existing hybrid-type iterative reconstruction (HIR) technique, when applied to brain CT images for diagnosis of early CT signs, which generally exhibit low-contrast lesions that are difficult to detect.
METHODS: The subjects comprised 27 patients having infarctions within 4.5 h of onset and 27 patients with no change in brain parenchyma. Images with thicknesses of 5 mm and 0.625 mm were reconstructed by HIR. Images with a thickness of 0.625 mm reconstructed by filter back projection (FBP) were processed by INR. The contrast-to-noise ratios (CNRs) were calculated between gray and white matters; lentiform nucleus and internal capsule; infarcted and non-infarcted areas. Two radiologists subjectively evaluated the presence of hyperdense artery signs (HASs) and infarctions and visually scored three properties regarding image quality (0.625-mm HIR images were excluded because of their notably worse noise appearances).
RESULTS: The CNRs of INR were significantly better than those of HIR with P < 0.001 for all the indicators. INR yielded significantly higher areas under the curve for both infarction and HAS detections than HIR (P < 0.001). Also, INR significantly improved the visual scores of all the three indicators.
CONCLUSION: The INR incorporating a simple and reproducible algorithm was more effective than HIR in detecting early CT signs and can be potentially applied to CT images from a large variety of CT systems.
METHODS: The subjects comprised 27 patients having infarctions within 4.5 h of onset and 27 patients with no change in brain parenchyma. Images with thicknesses of 5 mm and 0.625 mm were reconstructed by HIR. Images with a thickness of 0.625 mm reconstructed by filter back projection (FBP) were processed by INR. The contrast-to-noise ratios (CNRs) were calculated between gray and white matters; lentiform nucleus and internal capsule; infarcted and non-infarcted areas. Two radiologists subjectively evaluated the presence of hyperdense artery signs (HASs) and infarctions and visually scored three properties regarding image quality (0.625-mm HIR images were excluded because of their notably worse noise appearances).
RESULTS: The CNRs of INR were significantly better than those of HIR with P < 0.001 for all the indicators. INR yielded significantly higher areas under the curve for both infarction and HAS detections than HIR (P < 0.001). Also, INR significantly improved the visual scores of all the three indicators.
CONCLUSION: The INR incorporating a simple and reproducible algorithm was more effective than HIR in detecting early CT signs and can be potentially applied to CT images from a large variety of CT systems.