DOI 10.1016/s1098-7339(98)90088-8
Blood flow velocity changes in carotid and vertebral arteries with stellate ganglion block: measurement by magnetic resonance imaging using a direct bolus tracking method.
Аннотация
BACKGROUND AND
OBJECTIVES
Stellate ganglion block (SGB) leads to vasodilation of the head and neck, as a result of a regional sympathetic blockade. However, in such cases, controversy remains concerning changes in cerebral and extracerebral blood flow in the head. We estimated the effect of SGB on blood flow in the head by measuring the blood flow velocity in cervical vessels, using magnetic resonance imaging and the direct bolus tracking method. This noninvasive method is free from potential artifacts of bones and other connective tissues.
METHODS
Seven adult patients with acute or chronic pain in the head or neck underwent SGBs, using an anterior paratracheal approach with 6-8 mL of 1% mepivacaine (3 right and 4 left SGBs). Blood flow velocity in common carotid and vertebral arteries (CCA and VA) was measured simultaneously before and after SGB, using the direct bolus tracking method.
RESULTS
On the side of SGB, blood flow velocity in CCA significantly increased (P < .002), whereas velocity in VA was unchanged after SGB. On the side contralateral to the SGB, significant changes in blood flow velocity in CCA and VA were never observed.
CONCLUSIONS
Blood from the VA flows primarily to cerebral vessels, whereas that from CCA goes to both cerebral and extracerebral vessels. Given the presumed differences in blood flow distribution through the VA and CCA, we assume that the observed CCA blood flow increases, ipsilateral to the SGB, primarily as a result of vasodilation of extracerebral vessels and independent of changes in brain blood flow.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.