MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jelectrocard.2003.08.006

Медицинская библиотека · Journal of electrocardiology · 2003

Electrocardiographic predictors of failure and recurrence in patients with idiopathic right ventricular outflow tract tachycardia and ectopy who underwent radiofrequency catheter ablation.

Vestal Marivic, Wen Ming-Shien, Yeh San-Jou, Wang Chun-Chieh, Lin Fun-Chung, Wu Delon

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This study reports new electrocardiographic (ECG) predictors of radiofrequency catheter ablation failure and recurrence in idiopathic right ventricular outflow tract (RVOT) ventricular tachycardia (VT) or ectopy based on 91 consecutive patients. Procedural success and failure rates were 85% (77/91) and 15% (14/91), respectively. Twenty three percent (18/77) had recurrence during the follow-up period of 1 to 120 months (mean 56 +/- 31 months). Baseline RVOT VT/ectopy on 12-lead ECG taken prior to ablation from 91 patients were retrospectively analyzed. Ablation performed with RVOT ectopy (isolated ectopies, bigeminy, trigeminy, or couplets) as template arrhythmia was more likely to fail (30% vs. 8%, P =.02) as opposed to RVOT VT (sustained or nonsustained). VT/ectopy-QRS morphology variation was more observed in failed ablations (36% vs. 7%, P =.001). Significantly wider mean VT/ectopy QRS in leads I, II, AVR, V2, V3, V5, and V6 were noted in failed ablation group. Mean R wave amplitude reached statistical significance only in lead II (22.0 +/- 5.1 mV for failed vs. 17.8 +/- 5.2 mV for successful outcomes; P =.009). QRS morphologic variation (47% vs. 16%; P =.009) was the only statistically significant ECG to be more common in patients with arrhythmia recurrence. In conclusion, ablation with ectopy over VT as template arrhythmia, presence of QRS morphologic variation, wider mean QRS width, and taller mean R-wave amplitude in lead II were identified ECG predictors of failed RVOT VT/Ectopy ablation. The only ECG predictor of recurrence was the presence of RVOT VT or ectopy QRS morphologic variation.

Для цитирования: Vestal Marivic, Wen Ming-Shien, Yeh San-Jou, Wang Chun-Chieh, Lin Fun-Chung, Wu Delon. Electrocardiographic predictors of failure and recurrence in patients with idiopathic right ventricular outflow tract tachycardia and ectopy who underwent radiofrequency catheter ablation.. Journal of electrocardiology. 2003. DOI: 10.1016/j.jelectrocard.2003.08.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.