Audiometry with nasally presented masking noise: novel diagnostic method for patulous eustachian tube.

Hori Yoko, Kawase Tetsuaki, Hasegawa Jun, Sato Toshinori, Yoshida Naohiro, Oshima Takeshi, Suetake Mitsuko, Kobayashi Toshimitsu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Nasal-noise masking audiometry was developed to assess the acoustic transfer function from the nasopharyngeal cavity to the middle ear via patulous eustachian tube (ET).

STUDY

DESIGN

Prospective.

SETTING

Tertiary referral center.

PATIENTS: Twenty-seven ears of 18 patients with patulous ET and 20 ears of 10 healthy subjects with no history of ear disease or complaints of aural symptoms.

MAIN OUTCOME MEASURES: Audiometric measurement was conducted with and without masking noise presented in the nasal cavity.

RESULTS

The masking effect of nasally presented noise caused elevation of the threshold for the tone presented in the external auditory canal. This threshold elevation was significantly greater, particularly in the lower-frequency region, in ears with patulous ET and was decreased to the normal range after obstructive treatment of the patulous ET.

CONCLUSION

Nasal-noise masking audiometry is a simple and effective way to identify patulous ET.

Для цитирования: Hori Yoko, Kawase Tetsuaki, Hasegawa Jun, Sato Toshinori, Yoshida Naohiro, Oshima Takeshi, Suetake Mitsuko, Kobayashi Toshimitsu. Audiometry with nasally presented masking noise: novel diagnostic method for patulous eustachian tube.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2006. DOI: 10.1097/01.mao.0000226301.21080.1c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.