MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.compbiomed.2021.104693

Медицинская библиотека · Computers in biology and medicine · 2021

Effect of tube length on the buckling pressure of collapsible tubes.

Zarandi M Amin F, Garman Kevin, Rhee John S, Woodson B Tucker, Garcia Guilherme J M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The higher incidence of obstructive sleep apnea (OSA) in men than in women has been attributed to the upper airway being longer in men. The Starling resistor is the paradigm biomechanical model of upper airway collapse in OSA where a collapsible tube (representing the pharynx) is located between two rigid tubes (representing the nasal cavity and trachea). While the Starling resistor has been extensively studied due to its relevance to many physiological phenomena, the effect of tube length on tube collapsibility has not been quantified yet.

METHODS

Finite element analysis of a 3-dimensional collapsible tube subjected to a transmural pressure was performed in ANSYS Workbench. The numerical methods were validated with in vitro experiments in a silicone tube whose modulus of elasticity (361 ± 28 kPa) and dimensions (length = 100 mm, diameter = 22.2 mm, and wall thickness = 1.59 mm) were selected so that tube compliance was similar to pharyngeal compliance in humans during sleep. The buckling pressure (transmural pressure at which the tube collapses) was quantified in tubes of three different diameters (10 mm, 16 mm, and 22.2 mm) and ten length-to-diameter ratios (L/D = 4 to 13), while keeping the wall-thickness-to-radius ratio constant at 0.143.

RESULTS

The absolute value of the buckling pressure decreased from 4.7 to 3.3 cmH2O (461-324 Pa) when L/D increased from 4 to 13. The buckling pressure was nearly independent from tube length for L/D >10.

CONCLUSIONS

Our finding that longer tubes are more collapsible than shorter tubes is consistent with the higher incidence of obstructive sleep apnea in males than females.

Для цитирования: Zarandi M Amin F, Garman Kevin, Rhee John S, Woodson B Tucker, Garcia Guilherme J M. Effect of tube length on the buckling pressure of collapsible tubes.. Computers in biology and medicine. 2021. DOI: 10.1016/j.compbiomed.2021.104693.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.