McGrath Video Laryngoscopy Facilitates Routine Nasotracheal Intubation in Patients Undergoing Oral and Maxillofacial Surgery: A Comparison With Macintosh Laryngoscopy.

Kwak Hyun-Jeong, Lee Seong-Yeon, Lee Sook-Young, Cho Sang-Hyun, Kim Hong-Soon, Kim Jong-Yeop

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: The McGrath video laryngoscope (VL) offers excellent laryngoscopic views and increases the success rate of orotracheal intubation in patients with normal and difficult airways. The purpose of this randomized controlled trial was to compare the McGrath VL with the Macintosh laryngoscope to investigate the efficacy of the McGrath VL for routine nasotracheal intubation in patients with an expected normal airway.

MATERIALS AND

METHODS

To address the research purpose, the efficacy of the McGrath VL for routine nasotracheal intubation was compared with that of the Macintosh laryngoscope. The predictor variable was the laryngoscopic technique (McGrath VL vs Macintosh laryngoscope). The outcome variables were the time to successful intubation, laryngoscopic views before and after optimal external laryngeal manipulation (OELM), use of Magill forceps, ease of intubation, and severity of oropharyngeal bleeding.

RESULTS

Data from 35 patients undergoing oral and maxillofacial surgery were assessed. The time to intubation was 10.5 seconds shorter in the McGrath group than in the Macintosh group (34.4 ± 13.7 vs 44.9 ± 15.6 seconds; P = .004). The incidence of grade 1 glottic view before OELM was higher in the McGrath group than in the Macintosh group (83 vs 57%; P = .019). The frequency of Magill forceps use was lower in the McGrath group than in the Macintosh group (6 vs 34%; P = .003).

CONCLUSION

McGrath VL facilitates routine nasotracheal intubation in expected normal airways by providing a shorter intubation time and better laryngoscopic views compared with the Macintosh laryngoscope.

Для цитирования: Kwak Hyun-Jeong, Lee Seong-Yeon, Lee Sook-Young, Cho Sang-Hyun, Kim Hong-Soon, Kim Jong-Yeop. McGrath Video Laryngoscopy Facilitates Routine Nasotracheal Intubation in Patients Undergoing Oral and Maxillofacial Surgery: A Comparison With Macintosh Laryngoscopy.. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 2015. DOI: 10.1016/j.joms.2015.07.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.